Performance Work Statement
Updated
A Word document (17 KB) attached to Heat Flux Transducers, from the Forest Service. Due Nov 6, 2026, 2:00 PM (UTC-8).
File name: Performance Work Statement.docx
The full file is for paid members, or buy this bid alone.
Preview
PERFORMANCE WORK STATEMENT
Missoula Fire Sciences Laboratory
5775 US Hwy 10 West
Missoula, MT 59808
TITLE: Heat Flux Transducers for Fire Research
OBJECTIVES STATEMENT:
Our team needs more heat flux transducers. Heat flux transducers or gauges are highly calibrated sensors that allow us to measure quantities of heat energy being transferred.
BACKGROUND:
These instruments are used frequently to conduct experiments in fire behavior and are a critical part of subprojects that influence and guide research activities within fire behavior study. Additional sensors are needed for scheduled projects to measure the amount of heat that a fuel sample is experiencing from one of our custom-built burners, or to evaluate heat output of an advancing fire in a pine needle bed for two examples.
DESCRIPTION OF SERVICES OR PRODUCT/TASKS:
Quantity 4 water cooled radiant and total heat flux transducers with sapphire window for the radiant sensor, 25.4 mm diameter, smooth body, no flange with measuring range up to 250 kW/m^2
Quantity 2 water cooled radiant heat flux transducers with sapphire window in the range of 3.175mm diameter with measuring range up to 250 kW/m^2
REQUIREMENTS:
Heat flux transducers must have capabilities as described above with ability to withstand body temperatures up to 205 C. Output signal must be linear with a maximum nonlinearity of ± 3%. The radiant sensor should be behind a sapphire window to focus on the relevant wavelengths. The heat flux transducers should be smooth bodied, without a flange, 4 should be 1” in diameter and the other 2 should be 1/8th”. The size for the 1” diameter transducer and being unthreaded (smooth) without a flange are very important for fitting into our existing hardware and simplifying the design process for new applications. The smaller transducers do not have existing equipment to fit in. All transducers should be gas purged when possible. The transducers should be Schmidt-Boelter in style for our measurement ranges.
DELIVERABLES:
6 total heat flux gauges of differing size and capabilities as specified above.
DELIVERY ADDRESS & HOURS OF OPERATION
Missoula Fire Sciences Laboratory
5775 US Hwy 10 West
Missoula, MT 59808
Deliveries only accepted Monday – Friday, 0800 – 1600, except Federal Holidays, with at least 3 business day of prior notice of delivery date.
As soon as possible, with the understanding that this may take up to six months to arrive.
CONTACTS
COR:
Name: Rebecka Woodenknife
Email: [email protected]
The beginning of the document. Download the full file to read on.