Fort Bliss Gravesite Expansion BD Part 11
Updated
A PDF document (7.9 MB) attached to Fort Bliss National Cemetery, Gravesite Expansion and FCA Deficiencies, from the Department of Veterans Affairs. Due Nov 12, 2026, 10:00 AM (UTC-7).
File name: Fort Bliss Gravesite Expansion BD Part 11.pdf
The full file is for paid members, or buy this bid alone.
Preview
EXISTING TELECOM
WALL FIELD
A
A
25-PAIR COPPER TO
ADMIN BLDG
WALL HEIGHT
106'-0"
COPPER
PROTECTION
MODULE
C2
NETWORK
SWITCH
INTRUSION
DETECTION
SYSTEM WITH
WIRELESS
FIBER PATCH CORD
NETWORK SWITCH
EXISTING TELECOM WALL FIELD.
MODULAR PATCH
PANEL
WAP FOR FIRE
ALARM PANEL
B
B
T301
FIBER OPTIC
PANEL
C2
(2) 6-STRAND FIBERS
TO ADMIN BLDG
2" CONDUIT
LEVEL
FIRST
LEVEL
100'-0"
100'-0"
R1
EXISTING EQUIPMENT ROOM LAYOUT
C
N
1/2" = 1'-0"
NOTES:
EXISTING TELECOM WALL FIELD ELEVATION
C
1" = 1'-0"
NOTES:
ORT H
1.
1.
REMOVE ALL LOW VOLTAGE CABLING AND DEVICES BACK TO ITS SOURCE AND REMOVE ALL EQUIPMENT. COORDINATE WITH VA OIT FOR THE REMOVAL OF ALL TELEPHONE AND NETWORK EQUIPMENT PRIOR TO CABLE REMOVAL.
REMOVE ALL LOW VOLTAGE CABLING AND DEVICES BACK TO ITS SOURCE AND REMOVE ALL EQUIPMENT. COORDINATE WITH VA OIT FOR THE REMOVAL OF ALL TELEPHONE AND NETWORK EQUIPMENT PRIOR TO CABLE REMOVAL.
LEVEL
CEILING
HEIGHT
110'-0"
110'-0"
KEYNOTES:
1.
2.
SWITCH LOCATED ON FILE CABINET ON ADJACENT WALL.
IDS SYSTEM LOCATED ON ADJACENT WALL.
SC-CT-1
12"x4"
SC-TTB
AC-SCP-1
SC-CAB-2
SC-LR-1
12"x1 1/2"
(TYP)
SC-GND-2
+84"
SC-LR-1
12"x1 1/2"
SC-LR-1
12"x1 1/2"
(TYP)
D
D
AC-SCP-1
SC-TTB
(TYP.)
WALL HEIGHT
106'-0"
SC-CAB-2
6/12/2026 10:51:23 AM
SC-GND-2
+84"
SC-FDC-1
SC-HWM-1
SC-MPP-1
SC-GND-3
GFGI NETWORK SWITCH
SC-CT-1
12"x4"
(TYP)
T301
TE
-
TE
-
SC-HWM-1
SC-NS-1
CM-1
01-07
SC-UPS
SC-PDU-1
SC-PDU-1
E
E
SC-UPS
F
PW-CPW-1
(TYP OF 2)
Autodesk Docs://24001019.06 - VA NCA Ft Bliss campus Expansion/ET23_24001019.06_VA NCA_250904-18528-MAINT_C.rvt
R1
LEVEL
FIRST
LEVEL
100'-0"
100'-0"
COMMUNICATIONS ROOM EQUIPMENT LAYOUT - TE/2
N
1/2" = 1'-0"
KEYNOTES:
ORT H
1.
N
MOUNT CAMERA TO UNDERSIDE OF CABLE TRAY.
ORT H
COMMUNICATIONS ROOM PATHWAY LAYOUT - TE/2
1/2" = 1'-0"
COMMUNICATIONS ROOM RACK LAYOUT - TE/2
1" = 1'-0"
KEYNOTES:
KEYNOTES:
1.
1.
2.
3.
2.
3.
INSTALL LADDER RACK VERTICALLY ON WALL BETWEEN SC-CAB-2 TO TOP OF SC-CT-1 ABOVE. REFER TO 5/T301 FOR MORE INFORMATION.
INSTALL LADDER RACK VERTICALLY ON WALL FROM BASE OF TTB TO TOP OF SC-CT-1 ABOVE. TWO (2) 2" CONDUITS PENETRATING WALL FROM HANDHOLE OUTSIDE. REFER TO CIVIL DRAWINGS CU102 FOR CONDUIT CONTINUATION.
4.
SC-GND-3 TO BE MOUNTED ON REAR OF RACK AT TOP RACK MOUNTING LOCATION. RACK SPACE RESERVED FOR FUTURE EQUIPMENT.
UPS RESERVED FOR SECURITY NETWORK SWITCH. CONTRACTOR TO SIZE UPS PER SPECIFICATIONS AND PROVIDE
The beginning of the document. Download the full file to read on.