PIP-II Cryogenic Distribution System
ED0049128 – CM 2K Reclosable Pressure Safety Relief
Valves Specification

PIP-II Cryogenic Distribution System

ED0049128 CM 2K Reclosable Pressure Safety Relief Valves specification

Document Approval
Signatures Required

Date Approved

Reviewer: Vrushank Patel, PIP-II L3M for CDS

As in Teamcenter

Reviewer: Alex Martinez, PIP-II CAM for CDS

As in Teamcenter

Reviewer: Matt Luedke, PIP-II Quality Assurance

As in Teamcenter

Reviewer: Jeremy Nudell, PIP-II Project Engineer

As in Teamcenter

Approver: Joe Ozelis PIP-II L2 for SRFCryo

As in Teamcenter

Originator: William Soyars, CDS engineer

Revision History
Revision
-

Date Released
8/26/2026

Fermi National Accelerator Laboratory

As in Teamcenter

Description
Initial release

PIP-II Cryogenic Distribution System

ED0049128 CM 2K Reclosable Pressure Safety Relief Valves specification

1.

Introduction and Scope

2.

Acronyms

3.

Cryogenic Relief Valve specific technical requirements

4.

Additional technical requirements, information, and clarifications

5.

In-situ testing provisions

6.

Labelling

7.

Transportation and handling

8.

Document deliverables

9.

In-coming Quality Check and Acceptance by FNAL

Fermi National Accelerator Laboratory

PIP-II Cryogenic Distribution System

ED0049128 CM 2K Reclosable Pressure Safety Relief Valves specification

1. Introduction and Scope

1.1.

PIP II Cryomodule (CM) Relief System

1.1.1.

Fermi National Accelerator Laboratory (FERMILAB) located in Batavia, IL is building a next generation proton accelerator called the Proton Improvement Plan II (PIP-II). The PIP-II accelerator (Linac) design is based on superconducting radio frequency (SRF) technology employed in up to twenty-five SRF cryomodules (CM). The linac requires cryogenic helium for operation. Figure 1.1 presents a schematic overview of the PIP-II CM relief system. The linac cryomodules (CMs) are equipped to protect accelerator components from overpressure. There are 25 CMs in the accelerator tunnel. The reliefs are circled in Figure 1.1. The process line normally operates at sub-atmospheric cryogenic conditions, about 30 mbar absolute pressure and 2 K (-459 oF).

Figure 1-1 PIP-II Relief System, with Cryomodule pressure relief valve indicated

Fermi National Accelerator Laboratory

PIP-II Cryogenic Distribution System

1.2.

ED0049128 CM 2K Reclosable Pressure Safety Relief Valves specification

Scope and Quantity

1.2.1.

This specification is for cryogenic reclosable relief valves on the Cryomodules (CM) helium bath volume.

1.2.2.

Twenty-five relief valves are required. Details to follow.