Department of Veterans Affairs
West Haven VA Medical Center

Solicitation #W912WJ26RA008/VA #VAWH-689-040
Phase A2-Chilled Water Plant Replacement

(17) Conductors and cables for electronic safety and security

systems: Section 28 05 13, CONDUCTORS AND CABLES FOR ELECTRONIC

SAFETY AND SECURITY.
(18) Low impedance path to ground for electronic safety and security system ground fault currents: Section 28 05 26, GROUNDING AND BONDING FOR SECURITY SYSTEMS.
(19) Conduits and partitioned telecommunications raceways for Electronic Safety and Security systems: Section 28 05 28.33, CONDUITS AND BACK BOXES FOR ELECTRONIC SAFETY AND SECURITY. (20) Physical Access Control System field-installed controllers connected by data transmission network: Section 28 13 00, PHYSICAL ACCESS DETECTION.
(21) Detection and screening systems:
ACCESS DETECTION.

Section 28 13 53, SECURITY

(22) Intrusion sensors and detection devices, and communication links to perform monitoring, alarm, and control functions: Section 28 16 11, INTRUSION DETECTION EQUIPMENT AND SYSTEMS.
(23) Video surveillance system cameras, data transmission wiring, and control stations with associated equipment: Section 28 23 00, VIDEO SURVEILLANCE EQUIPMENT AND SYSTEMS.
(24) Duress-panic alarms, emergency phones or call boxes, intercom systems, data transmission wiring and associated equipment:

Section 28 26 00, ELECTRONIC PERSONAL PROTECTION EQUIPMENT AND

SYSTEMS.
(25) Alarm initiating devices, alarm notification appliances, control units, fire safety control devices, annunciators, power supplies, and wiring: Section 28 31 00, FIRE DETECTION AND ALARM. (26) Emergency Call telephones, intercom systems, with blue strobe light and equipment: Section 28 52 31, SECURITY EMERGENCY CALL/DURESS ALARM/COMMUNICATIONS SYSTEM AND EQUIPMENT.
1.6

ADMINISTRATIVE REQUIREMENTS

a.

Assign a single communications project manager to serve as point of contact for Government, contractor, and design professional.

b.

Be proactive in scheduling work.
(1) Use of premises is restricted at times directed by Contracting Officer.
(2) Movement of materials:
to site.

Unload materials and equipment delivered

(3) Coordinate installation of required supporting devices and sleeves to be set in poured-in-place concrete and other structural components, as they are constructed.
(4) Sequence, coordinate, and integrate installations of materials and equipment for efficient flow of Work.

SECTION 27 05 11

Department of Veterans Affairs
West Haven VA Medical Center