Amendment 6: Drawing M-503 (Revised)
Updated
A PDF document (308 KB) attached to Construction of Chilled Water Plant and Site Utility Upgrades at VA Medical Center in West Haven, CT, from the Department of the Army. Due Nov 20, 2026, 1:00 PM (UTC-5).
File name: Amendment 0006 - Drawing M-503 (Revised).pdf
The full file is for paid members, or buy this bid alone.
Preview
FLOW DIAGRAM SYMBOLS LIST
A
COMPRESSED AIR
PRESSURE REDUCING VALVE (LIQUID/GAS)
D
DRAIN
"WYE" - STRAINER
FUEL OIL FILL
"WYE" - STRAINER W/SHUTOFF VALVE
AND HOSE CONNECTION WITH CAP
FLEXIBLE CONNECTION
FUEL OIL OVERFILL PREVENTION
VALVE, TYPICAL.
WL
ILD
FUEL OIL RETURN
FOS
FUEL OIL SUPPLY
HPC
HIGH-PRESSURE CONDENSATE
HPS
HIGH-PRESSURE STEAM
REDUCER - REFERENCE SPECIFICATION
FOR CONCENTRIC/ECCENTRIC AND FOT/FOB
PITCH PIPE IN DIRECTION
METER
1 1/4"FOR
3"FOR
PRESSURE GAUGE (FURNISHED WITH BALL VALVE)
UNION/FLANGE
SUCTION DIFFUSER WITH SUPPORT FOOT
AUTOMATIC AIR VENT
SHUTOFF VALVE NORMALLY OPEN
SHUTOFF VALVE NORMALLY CLOSED
3"FOR
PRESSURE/TEMPERATURE TEST PLUG
EXTERNAL EMERGENCY VALVE
SYMBOL:
DESCRIPTION:
A
TO/FROM DEDICATED ELECTRIC FUEL
OIL HEATING SYSTEM (1 SYSTEM PER
TANK), TYPICAL. REFER TO C1/M503.
TK-1
FOR
DIRECTION OF FLOW IN PIPE
TANK CONTROLLER LIST
HL
3"FOF
FOF
FL
DESCRIPTION:
HH
A
1 1/4"FOS
SYMBOL:
3"FOF
FL
FLUID LEVEL TRANSMITTER
HH
HIGH-HIGH LEVEL ALARM SWITCH
HL
HIGH LEVEL SWITCH
ILD
INTERSTITIAL LEAK DETECTOR
WL
WATER LEVEL TRANSMITTER
FUEL OIL PIPING THAT DOES NOT CIRCULATE THROUGH FUEL
OIL HEATER CABINETS SHALL BE INSULATED AND HEAT
TRACED, TYPICAL. (REPRESENTED BY DOUBLE-DASHED LINES.)
MANUAL AIR VENT W/ BALL VALVE
FP-1
THROTTLING VALVE
0.5
0.5
DRAIN WITH HOSE CONNECTION, CAP &
BALL VALVE
AUTOMATIC BALANCING VALVE (NO. INDICATES GPM)
BALANCING VALVE (NO. INDICATES GPM)
TEMPERATURE SENSOR WITH WELL
CONTROL VALVE (THREE-WAY)
2"FOR
THERMOMETER WITH WELL (FILLED TYPE)
3/4" NORMALLY CLOSED MANUAL DRAIN
VALVE TO ALLOW FOR SERVICING PIPE
COMPONENTS, TYPICAL.
CONTROL VALVE (TWO-WAY)
SOLENOID/TWO POSITION VALVE
B
AUTOMATIC FUEL
OIL POLISHER.
REFER TO 2/MP-605.
3"FOS
FLOW METER
2"FOS
B
FL
CHECK VALVE
VACUUM SWITCH
FL
2"FOR
HH
SAFETY/RELIEF VALVE
HH
WL
PRESSURE TRANSMITTER
WL
HL
HL
2"FOS
ILD
1 1/4"FOR
C
PUMP
RUNNING
FOH-#
R
HIGH
HIGH
VACUUM PRESSURE
ALARM
RESET
HAND-OFFAUTO
R
G
BASIN
LEAK
HEATER
ENERGIZED
2"FOS
3"FOF
3"FOR
3"FOS
WATER LEVEL
TRANSMITTER
C
3"FOS
INDICATORS AND SWITCHES MOUNTED
ON FUEL OIL HEATER PANEL FACE
INSULATED FOS&R PIPING TO/FROM ABOVEGROUND
FUEL OIL STORAGE TANK, TYPICAL OF 5.
FUEL LEVEL
TRANSMITTER
3"FOF
SYSTEM
POWER
R
1 1/4"FOR
C1
G
90% & 95% LEVEL
SWITCHES
3"FOR
E-STOP
1 1/4"FOS
THERMOSTAT PROVIDE BY OIL
HEATER MANUFACTURER.
460V/3Ø
POWER
G
1 1/4"FOR
1 1/4"FOR
1 1/4"FOR
3"FOF
H. O. A.
2"FOR
ELECTRIC OIL
HEATER
TK-3
1 1/4"FOR
0-100
PSI
3"FOR
FOP-#
30"HG-0- (10 GPM)
60 PSI
3"FOR
PANEL LAMPS SHALL BE:
•
18mm LED WITH PUSH-TO-TEST FUNCTION.
•
G - GREEN
•
R - RED
DASHED LINES REPRESENT A UL LISTED TYPE 304
The beginning of the document. Download the full file to read on.
Other documents in this bid
- JA (Class) - Interior Finishes Redacted
- JA 01 - Siemens or JCI HVAC BAS Redacted
- JA 02 - JCI Fire Redacted
- JA 03 - JCI ESS Redacted
- JA 04 - Assa Abloy Redacted
- JA 05 - AMAZ Redacted
- Specifications - Volume I
- Specifications - Volume II
- Amendment 1: Submission Requirements and Evaluation Criteria
- Amendment 1
- Amendment 2: Bidding Schedule
- Amendment 2: Specifications Section 01 22 00