ATR Loop Pressurizer Fabrication
Expression of Interest (EOI)

ATR Loop Pressurizer Fabrication
Expression of Interest (EOI)

INTRODUCTION

Battelle Energy Alliance, LLC (BEA), Management & Operating Contractor of the U.S. Department of Energy (DOE) owned Idaho National Laboratory (INL), is seeking an Expression of Interest (EOI) from qualified vendors capable of fabricating an ASME Section VIII, Division 2 pressure vessel for use as the ATR Loop Pressurizer (1A-NE Loop). The fabricated vessel will play a critical role in maintaining system pressure, degassing, and surge compensation for an Advanced Test Reactor (ATR) experiment loop.

BACKGROUND

INL is a U.S. Department of Energy (DOE) national laboratory dedicated to nuclear energy, national security, and clean energy innovation. The ATR experiment loops rely on a dynamic pressurizer system to maintain primary coolant pump pressure, provide a means of degassing the primary coolant, and compensate for pressure surges. BEA is requesting vendor capability statements for the fabrication of a vertically oriented, leg-mounted pressure vessel with radial side arms, built to strict nuclear, metallurgical, and structural performance standards. Projectspecific INL drawings, design calculations, and procedural references will be furnished to selected vendors.
The scope of work includes the following:
• Fabrication, inspection, and physical testing of one (1) ASME Section VIII, Division 2 stainless steel pressure vessel with associated appurtenances (vessel, mounting leg stand, spray nozzles, lifting lugs), per INL Drawings 1050604, 1050605, and 1050606 • Supply of all materials associated with the vessel and appurtenances • Hydrostatic testing at room temperature in accordance with ASME code (minimum test pressure 3415 psig, +100/-0 psig tolerance)
• Load testing and documentation of lifting lugs
• Shop drawing development and submission through INL's vendor data system • Shipping/handling pallet and container for horizontal-orientation transport, forkliftcompatible • Delivery to WestOne Logistics, Idaho Falls, ID

ATR Loop Pressurizer Fabrication
Expression of Interest (EOI)

The scope of work does not include the following:
• Installation at the Contractor's facility
• Procurement and installation of clamp-on heaters
• Vessel insulation
• Design, seismic analysis, thermal analysis, stress analysis, or fatigue analysis • Overpressure protection (provided by a separate direct spring relief valve)