STATEMENT OF WORK
Vacuum Recovery Unit
1. SCOPE.
1.1. Portsmouth Naval Shipyard (PNSY) is seeking to lease vacuum recovery unit and associated components as listed in Component List 3.1 including Start-up/commissioning, training, preventative maintenance and weekly equipment inspections for use at Portsmouth Naval Shipyard (PNSY) in Kittery, ME. Quantities are listed in paragraph 3.1 component list. The minimum allowable requirements for the system are detailed in this Statement of Work. Unless otherwise stated, the contractor shall furnish the system, including all labor, supervision, tools, materials, equipment and other items and services that are necessary to perform as described within this Statement of Work.
2. APPLICABLE DOCUMENTS.
2.1. Issues of Publications. The following documents in effect on the date of this requested proposal is a part of this specification to the extent applicable, or as specified herein. Within the specification, they shall be referred to by their basic designation only.
2.1.1. Government Furnished
2.1.1.1. Corporate Lifting and Handling Manual
2.1.2. Nongovernment Furnished
2.1.2.1. National Electrical Manufacturers Association (NEMA); NEMA 3
2.1.2.2. National Electrical Code (NEC)
2.1.2.3. American Society of Mechanical Engineers (ASME) 2.2. Order of precedence. In the event of conflict between the Statement of Work (SOW) and the references cited above, the text of this SOW shall take precedence. Nothing in this SOW, however, shall supersede applicable laws or regulations unless a specific exemption has been obtained.
3. REQUIREMENTS.
3.1. Vacuum Recovery Unit Component List.
PIECE NO.
PC-1 thru 4
PC-5 thru 8
QTY.
NAME OF PART
200HP Vacuum Recovery Unit (VRU)
VRU E-stop and cabling
PARA NO.
3.2
3.2.3
3.2. Vacuum Recover Unit (VRU)
3.2.1. General Description of System: The equipment shall meet all the performance and construction characteristics herein. The equipment shall be portable and provide for full recovery of abrasive blast grit, which may be located up to 400 feet away from the equipment. All values given are intended as the actual value, unless specified as a range, maximum or minimum.
3.2.2. General Requirements
3.2.2.1. SKID MOUNTED: UL approved with adequate (rectangular tube) frame, fork pockets and certified lifting cage.
3.2.2.2. OPERATION: Continuous. Shall incorporate provisions to protect blower from overheating. The system shall not require water for cooling or for vacuum operation. 3.2.2.3. HOSE DISTANCE: The vacuum will transport the grit through a minimum 400 feet of 6 inch