Attachment 3: P1 Drawing 27320-2 Access Notes
Updated
A PDF document (445 KB) attached to 460-24-009 CLC and Fourth Floor Patient Elopement System, from the Department of Veterans Affairs. Due Nov 12, 2026, 1:00 PM (UTC-5).
File name: Attachment 3 P1 Drawing 27320-2 Access Notes 102025.pdf
The full file is for paid members, or buy this bid alone.
Preview
X
Single Model T80
Touchpad Exit Controller (TEC)
Qty.
RB-8
RB-8 Deactivation Relay
Qty.
V
Virtualized Server
Qty.
Client PC Supplied by Customer
(configured for Enterprise)
Qty.
Staff Alert Panel 8-Zone
Qty.
Proximity Card Reader (PC)
Qty.
Central Power Supply
Qty.
RS-485 Hub
Qty.
Serial Terminal Server
Qty.
16 Port Switch Box
Qty.
Patch Panel
Qty.
Customer
CLIENT
Location 2
CR(E) x2 Card In/Out
ML(E) Maglock Always Locked
Integrate with
Access Control &
Lock (by others)
SafePlace
EXIT
RB-8
PROX
READER
1 2 3 4
STS
(DIGI)
RB-8
16 PORT SWITCH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Integrate with
Access Control &
Lock (by others)
Location 1
CR(E) Card Out
ML(E) Maglock Always Locked
Mon(N) Active Alarms to ACP
(N) New
(E) Existing
Card Reader to Reset/Bypass Wander System
Wander Alarms Report to Lenel Access System
(a) Tag in field door closed (Alarm to Lenel after 60-Seconds) (b) Tag in field door opened (Alarm to Lenel instant)
SD
Included in the 8 Zone Wall Panel
Location 4
CR(N) Card Out
ML(E) Delayed Egress Maglock Locked on Schedule
CLC 27Head End Accessand
Wonder SystemEmergency
Power Required
Integrate with
Access Control &
Lock (by others)
RB-8
RB-8
Location 5
CR(N) Card Out
ML(E) Delayed Egress Maglock Always Locked
New Card Readers (6)
New Mag locks (2)
New EEB Pull (2)
New Lenel-1320 (3)
New Lenel-1100 (1)
New LSP 8-Door (1)
New Door Contacts (9)
Integrate with
Access Control &
Lock (by others)
SD
X
RB-8
SD
X
Integrate with
Access Control &
Lock (by others)
Location 3
CR(N) Card Out
ML(E) Delayed Egress Maglock Locked on Schedule
Location 6 and 7
Demo existing?
CR(N) x2
ML(N) x2
PROX
READER
NOTES:
1. For access control integration, we will provide a local relay at the door. A cable (15’ in length) will be attached to the relay and coiled in the overhead above each door. Final connection and programming to be provided by others.
2. Door systems may integrate with existing maglocks that are supplied and maintained by others. Power to the existing maglocks is also supplied by others. RFT only supplies power to our own maglocks. We provide a relay for integration. Final wiring and terminations provided by others.
Customer
SafePlace
EXIT
CLIENT
RB-8
SD
X
Integrate with
Access Control &
Lock (by others)
Head End Equipment
8 Zone
Wall Panel
CPS
16 PORT SWITCH
1 2 3 4
STS
(DIGI)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
LOCATION TO BE DETERMINED
(Centrally located within the coverage area)
The beginning of the document. Download the full file to read on.