SUBJECT*
Serranator PTA Serration Balloon Catheters
GENERAL INFORMATION
CONTRACTING OFFICE’S ZIP CODE*
32601-3460
SOLICITATION NUMBER*
36C24827Q0117
RESPONSE DATE/TIME/ZONE
11-11-2026 12PM EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
PRODUCT SERVICE CODE*
6515
NAICS CODE*
339113
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs
Network Contracting Office 8 (NCO 8)
Commerce Building
300 E. University Ave. Ste. 180
Gainesville FL 32601-3460
POINT OF CONTACT*
Contracting Officer
Shirley Courtney
[email protected]
352-219-7527
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
DESCRIPTION: Department Of Veterans Affairs, VISN8, Network Contracting Office 8, Prosthetics Department, Tampa, FL, hereby Gives Notice of Intent to Award a Sole Source to Cagent Vascular Inc, 50 Strafford Avenue Suite 315, Wayne, Pa 19087.
DELIVERABLES: The Serranator® PTA Serration Balloon Catheter is a peripheral angioplasty device from Cagent Vascular designed for the treatment of peripheral artery disease (PAD) and certain arteriovenous (AV) fistula lesions. Unlike a standard PTA balloon, it incorporates serrated scoring elements on the balloon surface that create controlled micro-incisions (micro-fissures) in the vessel wall during inflation. This approach is intended to improve lumen expansion while reducing recoil and uncontrolled dissections. HYPERLINK "https://cagentvascular.com/serranator" [cagentvascular.com], HYPERLINK "https://cagentvascular.com/resources" [cagentvascular.com]
KEY FEATURES
Serration Remodeling Therapy™ (SRT) technology.
Semi-compliant balloon with embedded serrated metal elements. Designed to generate focused point force rather than uniform circumferential stretching. Available in multiple balloon diameters and lengths for peripheral interventions. HYPERLINK "https://cagentvascular.com/serranator" [cagentvascular.com], HYPERLINK "https://fda.innolitics.com/device/K213728" [fda.innolitics.com] THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. The North American Industry Classification System (NAICS) number is 339113. A decision by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct competitive procurement. Parties may identify their interest, accompanied by supporting literature to the Contracting Officer no later than 11/11/2026 at 12:00 PM EST. Responses should be sent to [email protected]. Responses received will be evaluated; however, a determination by the Government not to compete the proposed procurement will be solely up to the government.