SUBJECT*
HVAC upgrades at VA Loch Raven location
GENERAL INFORMATION
CONTRACTING OFFICE’S ZIP CODE*
21201
SOLICITATION NUMBER*
36C24527Q0061
RESPONSE DATE/TIME/ZONE
12-14-2026 8am EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
SET-ASIDE
SBA
PRODUCT SERVICE CODE*
J065
NAICS CODE*
561210
PLACE OF PERFORMANCE
Department of Veterans Affairs
VAMC
10 N Greene St
Baltimore MD
POSTAL CODE
21201
COUNTRY
USA
CONTACT INFORMATION
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs
VAMC
10 N Greene St
Baltimore MD 21201
POINT OF CONTACT*
Contract Officer
Keysha Gorman
[email protected]
410-637-1513
ADDITIONAL INFORMATION
AGENCY’S URL
https://www.maryland.va.gov/locations/Loch_Raven_VA_Medical_
URL DESCRIPTION
Loch Raven VA Medical Center
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
Keysha Gorman
DESCRIPTION
The contractor will provide all material, labor, equipment, and supervision necessary to complete the above-named project at the VA Maryland Health Care System (VAMHCS), Building 1 Community Living Center (CLC) of the Loch Raven Campus.
Primary Deliverables and Project Requirements
Covid Ward 2nd floor B wing
Upgrade exhaust fans
Air Handling Unit (AHU-B) located in attic
Replace and upgrade EF-1A and EF-1B for higher CFM outputs Install heat tracing for chillers
Wiring and junction box located in room G-15. Chiller located outside CLC in the pit behind the service road. Assess current heat tracing for chill water line. Complete and terminate existing heat tracing wiring to an emergency electrical panel in G-17 in coordination with the VA. Panel selection is TBD. Install a 20-amp GFPE circuit breaker for the heat tracing to the panel selected by the VA. Kitchen basement
Replace cooling coil(s)
AHU-E located in attic.
Replace fan motor
AHU-E located in attic. AHU has one fan.
New motor must be rated for and capable of sustaining a fan speed of 60Hz. Replace Variable Frequency Drive (VFD)
VFD located in the attic and attached to the AHU
Replace VFD in kind with Manufacturer (ABB)
Controls Integration & Coordination
VA has an existing contract with Johnson Controls International (JCI). The contractor shall coordinate with the COR and Facility Maintenance to satisfy necessities for the facility’s existing Building Automation System (BAS) controls corresponding to all new work. Contractor will replace/reinstall or provide new hardware or connections for BAS monitoring when required to complete BAS programming or integration. This can include control wiring, modulators, switches, routing, existing equipment etc. These requirements are determined on a case-by-case basis.