Bid document
Updated
A PDF document (15 KB) attached to WXPAK, ASSY W/Hardwire Sensor, from the US Coast Guard. Due Nov 17, 2026, 12:00 PM (UTC-5).
File name: RD_6660-01-470-7062.pdf
The full file is for paid members, or buy this bid alone.
Preview
OVERHAUL DESCRIPTION
ITEM NAME
METEOROLOGICAL MEASURING SET
STOCK NUMBER
6660-01-470-7062
PART NUMBER
S1568
USED ON
WLB-225 & WLM-175
SHELF LIFE CD
Items as received by the contractor must be complete and of the proper cited part number. Discrepancies shall be reported to the Coast Guard Contracting Officer.
OVERHAUL REQUIREMENTS:
SPECIFICATION FOR OVERHAUL OF WEATHERPACK ASSEMBLIES
1.0 SCOPE
1.1 This statement of work covers the requirements to inspect governmentfurnished weather pack assemblies for completeness, furnish any needed parts, overhaul, test, preserve, package, mark, and bar code.
1.2 Government Furnished Property: WXPAX, ASSY w/ Hardwire Sensor, part number S1568, National Stock Number (NSN) 6660-01-470-7062
1.3 Description:
a.
The above cited assembly contains the following components:
Anemometer (Part Number 1220-117-025, consists of:)
S1104W - Wind Monitor, RMY 05103 2930-000-044 - Wind Monitor
Propeller
2930-000-102 - Wind Monitor Propeller Shaft Nut
b. Weatherpak Assembly (Part Number WP2000, parts listed below are considered replacement parts for WEATHERPAK and do not effect Form/Fit/Function rule for the system.) Consists of:
S1276W - SENSOR,RH/AT 3% (WP2000 S/N's prior to 3440)
S9276W - ASSY,WP2000,AIR TEMP, REL HUMIDITY, 2% (WP2000 S/N 34403456)
2930-000-058 - Filter, BP Pressure Port
1230-117-003 - Assy, WP2000, Radiation Screens
S1081W - Assy, Barometric Pressure Sensor
1230-117-006 - Assy, WP2000, Housing
1716-116-098 - PCB Assy, Z3200, CPU Board
1716-117-003 - PCB Assy, WP2000, I/F Board
c. Base Mount (Part number 1220-117-016, consists of:)
1220-117-001 - Assy, WP2000, Shipboard Quick Release
1230-101-009 - Quick Release Protective Cap
Note: Weatherpak base unit includes hardwire sensors:
S1276W - SENSOR,RH/AT 3% ORS9276W - ASSY,WP2000,AIR TEMP, REL
HUMIDITY, 2%
Barometer Pressure Sensor (Hardwired) P/N S1081W
2.0 APPLICABLE DOCUMENTS
a. ANSI/NSCL Z540-3, Calibration Laboratories, Measuring and Test Equipment General Requirements
FOR OFFICIAL USE ONLY
2.1 SPECIFICATION ORDER OF PRECEDENCE
- In the event of a conflict between
the text of this specification and the references cited herein, this
a. ANSI/NSCL Z540-3, Calibration Laboratories, Measuring and Test Equipment General Requirements 2.1 SPECIFICATION ORDER OF PRECEDENCE - In the event of a conflict between the text of this specification and the references cited herein, this specification shall take precedence.
3.0 REQUIREMENTS:
3.1 Arrival inspection: Upon receipt of GFP, the Contractor shall inspect
The beginning of the document. Download the full file to read on.