Home / 561-24-600 Upgrade Mechanical Systems-C Level / Document

Bid document

Updated

A Word document (26 KB) attached to 561-24-600 Upgrade Mechanical Systems-C Level, from the Department of Veterans Affairs. Due Jan 4, 2027, 10:00 AM (UTC-5).

File name: 36C24226R0127.docx

Download the full documentSee the bid

The full file is for paid members, or buy this bid alone.

Preview

SUBJECT*

561-24-600 Upgrade Mechanical Systems-C Level

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*

12208-3410

SOLICITATION NUMBER*

36C24226R0127

RESPONSE DATE/TIME/ZONE

01-04-2027 10:00 AM EASTERN TIME, NEW YORK, USA

ARCHIVE

90 DAYS AFTER THE RESPONSE DATE

SET-ASIDE

SDVOSBC

PRODUCT SERVICE CODE*

Y1DA

NAICS CODE*

238220

PLACE OF PERFORMANCE

Department of Veterans Affairs

New Jersey VA Health Care System

East Orange Campus

385 Tremont Ave.

East Orange NJ

POSTAL CODE

07018-1023

COUNTRY

USA

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS

Department of Veterans Affairs
Samuel S. Stratton VA Medical Center
113 Holland Avenue
Albany NY 12208-3410

POINT OF CONTACT*

Contract Specialist
Scott Nussbaum
[email protected]

ADDITIONAL INFORMATION

AGENCY’S URL

http://www.va.gov

URL DESCRIPTION

VA HOMEPAGE

AGENCY CONTACT’S EMAIL ADDRESS

[email protected]

EMAIL DESCRIPTION

Scott Nussbaum, Contract Specialist

DESCRIPTION

This notice is for Solicitation Number 36C24226R0127, Project Number 561-22-600 Upgrade Mechanical Systems-C Level at the VA NJ Health Care System, East Orange, NJ. This shall be a Service-Disabled Veteran Owned Small Business (SDVOSB) Set-Aside. As a result, all SDVOSB's may submit an offer, which will be considered by the agency. This project is classified under NAICS Code 238220 and has a size standard of $19 Million. The Magnitude of Construction for this project is between $5,000,000 and $10,000,000. Scope of Work:
The scope of work shall generally consist of, but not limited to the following: Project will renovate the existing C Level utility space located at C Level of Building 1 which will provide environmentally safe, comfortable, and compliant conditions for maintenance staff. The current HVAC equipment and plumbing systems are in poor condition causing continuous water & steam leakage. The improper function of pumps is leaving the pump-pit filled with water. Newly renovated space will optimize daily activities, routine maintenance of utilities and provide safe environment for maintenance staff at C Level at VA New Jersey Health Care System East Orange Campus. Contractor shall completely prepare site for building operations, including demolition and removal of existing structures, and furnish labor and materials to perform work for VA Project 561-24-600 Upgrade Mechanical Systems-C Level as required by AE drawings and specifications, including but are not limited to: Steam Header Replacement and Distribution
Condensate & Steam Piping Modification and Replacement of PRVs, Hangers & Valves

The beginning of the document. Download the full file to read on.