Combined Synopsis/Solicitation

RFQ ID #70ZH1527QCGA00009

Combined Synopsis/Solicitation
i.

This is a Combined Synopsis/Solicitation for services in accordance with the format in FAR Part 12, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation will not be issued.

ii.

Solicitation number 70ZH1527QCGA00009 is being issued as a Request for Quote (RFQ).

iii.

This solicitation document and the incorporated provisions and clauses reflect those in effect through Federal Acquisition Regulation (FAR) Revolutionary Overhaul https://www.acquisition.gov/far-overhaul

iv.

The North American Industry Classification System (NAICS) number is 238210 and the business size standard is $25.0 million. The proposed acquisition is being conducted as 100% Small Business Set-aside on a restricted basis.

v.

Product Service Code PSC is J061 and can be found at:
https://support.outreachsystems.com/resources/tables/pscs/

vi.

The Contract Line-Item Number (CLIN) structure shall include a total of eight (8), with anticipated CLIN structure for each ordering period is shown in the table below:

CLIN Description

Quantity Unit Unit Price Total

0001 Inspect and Repair of 13.2KV Main Switchgear 01
Total evaluated price

$[ ]

$[ ]
$[ ]

vii. Description of Requirement:
The U.S. Coast Guard Academy requires a qualified, licensed electrical contractor to inspect, repair as necessary, test, and restore Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear, with primary work focused on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor shall inspect Cabinet 5 for damage or missing/cannibalized components; remove and replace three Eaton 15CLE-250E fuses; procure and deliver three additional matching fuses for on-site spares; perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards; provide certified test and field-service reports; coordinate all required outages and lockout/tagout procedures with the Government; and safely re1

Combined Synopsis/Solicitation

RFQ ID #70ZH1527QCGA00009

energize the cabinet and feeder upon successful completion of repairs and testing. All work shall comply with applicable OSHA, NFPA 70E, federal, state, and local requirements, including proper licensed personnel, arc-flash personal protective equipment, site protection, cleanup, and disposal of waste materials.