A
A
three inches = one foot
6"
A
LL
RETE WA
CONC
B
B
B
SHED
6"
SHED
DUGOUT
Bath VAMC
FIRE PIT
one and one half inches = one foot
DUGOUT
SHED
GARDEN PLOT
BLOCK BUILDING
EMPTY TRANSFORMER
6"
C
C
C
6"
three quarters inch = one foot
one inch = one foot
FIREPLACE
DRAWING INDEX
D
one half inch = one foot
D
DESCRIPTION
G001
G002
A100
COVER SHEET & DRAWING INDEX
GENERAL NOTES
ARCHITECTURAL & DEMOLITON PLAN
A101
ICRA / LIFE SAFETY PLAN
A1
S1
S2
SD3
SD4
SD5
EN
EL
E1
E2
ED1
ED2
SITE LAYOUT
FLOOR & WALLS SUPPORT LAYOUT
CEILING SUPPORT LAYOUT - UNISTRUT
DETAIL - CEILING SUPPORT
DETAIL - WALL & FLOOR ANCHOR
DETAIL - WALL & FLOOR ANCHOR
ELECTRICAL NOTES
ELECTRICAL LEGEND
ELECTRICAL LAYOUT
RACEWAY DIAGRAM / CONDUIT LEGEND
ELECTRICAL DETAILS
ELECTRICAL DETAILS
E
F
F
CONSULTANT
Office of
Construction
and Facilities
Management
ARCHITECT/ENGINEER OF RECORD
STAMP
Revisions:
U.S. Department
of Veterans Affairs
Date:
Drawing Title
Phase
Project Title
Cover Sheet
Construction Drawings
Replace Flooring - RM 140
Approved:
Project Number
Location
NOTE:
Project Director
USERS OF THESE DRAWINGS ARE RESPONSIBLE FOR VERIFYING
528A6-26-607
Building Number
Drawing Number
Bath, NY
Issue Date
Checked
Drawn
Issue Date
AAA
MCC
G001
EXISTING DIMENSIONS AND CONDITIONS IN THE FIELD
one eighth inch = one foot
one quarter inch = one foot
three eighths inch = one foot
E
DISCIPLINE/
SHEET NO.
VA FORM 08 - 6231
D
E
MINIMUM SITE PREPARATION REQUIREMENTS:
1.
CONTRACTOR SHALL PERFORM ALL WORK IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL RULES, REGULATIONS, AND GUIDELINES, AS OUTLINED WITHIN THE CONTRACT DOCUMENTS.
1.
WALLS SHALL BE PAINTED OR COVERED, BASEBOARDS INSTALLED, FLOORS SHALL BE TILES AND/OR COVERED, CEILING SHALL HAVE GRID TILES AND LIGHTING FIXTURES INSTALLED AND OPERATIONAL.
2.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS (DIMENSION, QUANTITIES, ETC .. ) AND ESTABLISHING THE COMPATIBILllY OF ALL NEW WORK WITH THE EXISTING CONDITIONS.
2.
ALL ELECTRICAL CONVENIENCE, CONDUIT, RACEWAY, KNOCKOUTS, CABLE OPENINGS, CHASE NIPPLES, AND JUNCTION BOXES INSTALLED AND OPERATIONAL.
3.
CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL PERMITS, LICENSES, ETC .. REQUIRED BY REGULATING BODIES HAVING JURISDICTION.
3.
4.
CONTRACTOR IS RESPONSIBLE FOR ALL TOOLS, EQUIPMENT, AND SUPPLIES.
5.
CONTRACTOR SHALL PROVIDE ALL NECESSARY SCAFFOLDING AND STAGING, INCLUDING ERECTION AND DISMANTLING AS REQUIRED FOR THE WORK AND OWNER OCCUPANCY.
6.
CONTRACTOR IS RESPONSIBLE FOR KEEPING THE WORK AREA IN A CLEAN AND SAFE CONDITION.