CSSPTF Drawings - Amendment
Updated
A PDF document (1.3 MB) attached to Trade and Cargo Academy, from the Department of the Army. Due Nov 6, 2026, 12:00 PM (UTC-5).
File name: 261013 - CSSPTF Drawings - Amendment.pdf
The full file is for paid members, or buy this bid alone.
Preview
RWB
C
10/13/26
C
C
REVISED PER AMENDMENT 001
C
RTA
SUBMITTAL NOT
FOR
A CONSTRUCTION
SEAL
INDEX:
OF 106
4.
FOR TYPICAL MASONRY DETAILS, SEE SHEET S-506.
E
10/13/26
E
91'-5"
S-302
TYP 4-PLA
W10x68
COL
1'-2" WALL
TOP OF CONC
PAD EL 95'-4"
C
S-301
S-301
VERT
BRACING
(TYP)
TYP
S-301
S-301
LADDER UP TO
EL 117'-8 3/4"
2'-9"
2'-9"
*
FLOOD VENT
*
FLOOD VENT
2'-9"
2'-9"
*
FLOOD VENT
B
*
FLOOD VENT
B
S-201
FIRST FLOOR SLAB PLAN
1/8"=1'-0"
4'
8'
16'
- TOP OF 10" SLAB EL 100'-0" (DATUM)
DIMENSIONS TO BE COORDINATED WITH ACTUAL
EQUIPMENT PURCHASED AND WITH ARCH SHEETS
- L-X DENOTES STEEL ANGLE LINTEL, SEE STEEL LINTEL &
BEARING PLATE SCHEDULE ON S-505.
- FIRST FLOOR SLAB IS A STRUCTURAL DIAPHRAGM AND
PART OF THE SEISMIC FORCE RESISTING SYSTEM.
SAWCUTTING FOR FUTURE UNSPECIFIED WORK IS NOT
PERMITTED WITHOUT DETAILED ANALYSIS BY A
PROFESSIONAL ENGINEER.
SEE SHEET S-101 FOR ADDITIONAL PILE LOCATING
NOTES.
*
**
A
A
SEAL
Sheet
Reference No.
S-102
INDEX:
Description
Mark
FIRST FLOOR SLAB PLAN
CARGO SECURITY AND SEIZED PROPERTY TRAINING FACILTY
2000 BAINBRIDGE AVE, CHARLESTON, SC
DRAWING SCALES SHOWN BASED ON 22"x34" DRAWING
OF
RWB
DEB
Ckd by:
A
TYP
FOR RAMP RETAINING
WALLS, SEE S-101 FOR
ADDITIONAL INFORMATION
Reviewed by:
COORD PLACEMENT
OF REBAR WITH FLOOR
BOX LOCATIONS
STV Incorporated
7'-0 1/2"
5"± SLAB DEPRESSION AT ELEC FLOOR
BOX, TYP 21-PLA, COORD FLOOR BOX
LOCATIONS WITH ELEC CONTRACTOR
5/8"
A
S-302
DEB
5/8"
RAMP, SEE
CIVIL SHTS
6'-0"
CONC PAVEMENT,
SEE CIVIL SHTS
S-304
RECESSED AREA, DROP TOP REBAR
DOWN AT SLAB DEPRESSION TO
MAINTAIN CONC COVER, SEE
INTERIORS DRAWINGS FOR EXTENT
OF SLAB DEPRESSION REQUIRED
S-301
*
*
S-301
ADD'L REINF AT CORNERS
OF SLAB DEPRESSION, SEE
TYPICAL DETAIL ON S-501
16'-2 1/2"
SIGN, SEE
CIVIL SHTS
15'-10"
B
4'-6 1/2"
*
W10x68 COL
C LADDER
1'-2" WALL
11"
7'-3"
(3)-#6 @ 12 TOP & BOT REINFORCING
IN ADDITION TO THE TYPICAL FLOOR
SLAB REINFORCING, TYP 3-SIDES OF
RECESSED LOADING DOCKS
B.2
File: I:\Projects\D011751.000\D011751.000_0001\90_CAD Models and Sheets\06_S_Structural\CSSPTF\S-102 ; Plotted: 10/12/2026 5:36 PM by DOUGLAS BEAM ; Saved: 10/12/2026 5:34 PM
FD
1:1 (D SHEET)
HSS 8x3 POST FOR
MOVEABLE PARTITION
Plot scale:
7'-3"
Drawing code:
C
S-302
1'-7 1/2"
A
S-202
3'-1"
S-201
D
D011751.000
15'-2 1/2"
S-301
3'-0"
3'-11"
S-301
RECESSED LOADING
DOCK, 3 PLA
SLOPE
C.7
FD
2'-0"
3'-0"
6'-2"
10'-0"
2'-0"
14'-0"
16'-2 1/2"
The beginning of the document. Download the full file to read on.