STATEMENT OF WORK
Radiopharmaceuticals
George E. Wahlen
VA Salt Lake City Health Care System
500 Foothill Drive
Salt Lake City, UT 84148
General Information
The VA Salt Lake City Health Care System (VASLCHCS) seeks a Not To Exceed (NTE) base plus four (4) option year contract for the procurement of unit dose radiopharmaceuticals, radioactive sources, and supplies for diagnostic imaging exams and quality assurance procedures. Radiopharmaceuticals, or medicinal radio-compounds, are a group of pharmaceutical drugs containing radioactive isotopes. Radiopharmaceuticals can be used as diagnostic and therapeutic agents to diagnose specific pathologies, such as cancer, osteomyelitis, cardiac ischemia, and infection. The Contractor shall provide all resources necessary to accomplish the deliverables described in this statement of work.
General Requirements
•
The Contractor shall have an adequate supply of products to meet the requirements of the VASLCHCS. Contractor must provide a proposed supply chain contingency plan for all proposed line items. This is to ensure continuing and uninterrupted radiological clinical care.
•
Due to the required stat low energy unit doses for same day patient orders, contractor shall be located within a reasonable milage so that delivery requirements can be maintained.
•
Calibration time for each requested radiopharmaceutical is given in the Schedule of item, or if not so indicated, then it will be spelled out in the requirements provided by the Nuclear Medicine Service, otherwise it will correspond to the actual time of delivery.
•
If dosage is given to Contractor, then the quantity of radioactivity must be within the dose provided at the calibration time. If dose is not given in a range, then the quantity of radioactivity for supplied radiopharmaceuticals will not deviate more than ±10%.
•
The expiration date and time shall be indicated and affixed to each product. Contractor will use commercially reasonable efforts to achieve identified expiration times.
•
If a quality control or material defect is reasonably suspected and/or detected by any Veterans Affairs COTR, the Contractor will be requested to provide any consultation necessary to alleviate any said suspicion and/or defect by the following:
o
Provide technical expertise in calibration.
o
Provide credit for any product confirmed to be deficient.
o
Provide professional examination of product; submit results and recommendations to the Contracting Officer. In the event product is found to be compliant after examination under