Home / Office Space For US Army COE - Lenoir City, TN Area / Document

GSA 3626 Lease Form

Updated

A PDF document (419 KB) attached to Office Space For US Army COE - Lenoir City, TN Area, from the Department of the Army. Due Oct 27, 2026, 10:00 PM (UTC-5).

File name: GSA 3626 Lease Form_27OCT26.pdf

Download the full documentSee the bid

The full file is for paid members, or buy this bid alone.

Preview

1.

U.S. GOVERNMENT LEASE FOR REAL PROPERTY

(Short Form)

LEASE NUMBER

DACW62-5-26-001

PART I - SOLICITATION/DESCRIPTION OF REQUIREMENTS (To be completed by Government)

A. REQUIREMENTS

1,525
rentable square feet of

1 Jan 2027

(date) for a term of

1 yr + 4 options

1,525
square feet of
ANSI/BOMA Office Area (ABOA) for use by Tenant for personnel, furnishing, and equipment.

27 October 2026

B. STANDARD CONDITIONS AND REQUIREMENTS

4. The following standard conditions and requirements shall apply to any premises offered for lease to the UNITED STATES OF AMERICA (the GOVERNMENT): a. Space offered must be in a quality building of sound and substantial construction meeting the Government’s requirements for the intended use. b. The Lessor shall provide floor plans for the offered space and a valid Certificate of Occupancy for the intended use of the Government and shall meet, maintain, and operate the building in conformance with all applicable current (as of the date of this solicitation) codes and ordinances. If space is offered in a building to be constructed for lease to the Government, the building must be in compliance with the most recent edition of the building code, fire code, and ordinances adopted by the jurisdiction in which the building is located.
c. Offered space shall meet or be upgraded to meet the applicable egress requirements in National Fire Protection Association (NFPA) 101, Life Safety Code or an alternative approach or method for achieving a level of safety deemed equivalent and acceptable by the Government. Offered space located below-grade, including parking garage areas, and all areas referred to as "hazardous areas" (defined in NFPA 101) within the entire building (including non-Government areas), shall be protected by an automatic sprinkler system or an equivalent level of safety. Additional automatic fire sprinkler requirements will apply when offered space is located on or above the 6th floor. Unrestricted access to a minimum of two remote exits shall be provided on each floor of Government occupancy. Scissor stairs shall be counted as only one approved exit. Open-air exterior fire escapes will not be counted as an approved exit. Additional fire alarm system requirements will apply when offered space is located 2 or more stories in height above the lowest level of exit discharge. d. The Building and the leased space shall be accessible to persons with disabilities in accordance with appendices C and D of 36 CFR Part 1191 (ABA Chapters 1

The beginning of the document. Download the full file to read on.

Other documents in this bid