SECTION J-1607000
CHILLER
ATTACHMENT
NUMBER
J-1607000-01
J-1607000-02
J-1607000-03
J-1607000-04
J-1607000-05
J-1607000-06
J-1607000-07
J-1607000-08
ATTACHMENT TITLE
DEFINITIONS AND ACRONYMS
REFERENCES AND TECHNICAL DOCUMENTS
CHILLER PLANT AND DISTRIBUTION SYSTEM DESCRIPTION
CHILLER PLANT AND DISTRIBUTION SYSTEM ASSET DATA
CHILLER UTILITIES OVERVIEW DOCUMENT
HISTORICAL TEMPERATURE AND HUMIDITY CONTROL
REQUIREMENTS
SAMPLE DAILY LOG
COOLING TOWER WATER TESTING AND TREATMENT ASSET DATA
ATTACHMENT J-1607000-01
DEFINITIONS AND ACRONYMS
SEE SEPARATE ATTACHMENT J-0200000-01
ATTACHMENT J-1607000-02
REFERENCES AND TECHNICAL DOCUMENTS
SEE SEPARATE ATTACHMENT J-0200000-03
ATTACHMENT J-1607000-03
CHILLER PLANT AND DISTRIBUTION SYSTEM DESCRIPTION
The NSAA chiller plant and distribution system includes all mechanically and electrically interlocked ancillary parts, equipment and components required for safe and continuous operation of chilled water production, treatment, storage, and distribution including but not limited to: chillers, pumps, cooling towers, actuators, valves, controls, monitoring systems (to include computers, workstations, servers, and software), piping, insulation, chemical systems, ventilation and temperature control for plants. The chiller plant and distribution system serve the United States Naval Academy by generating and distributing chilled water to approximately 33 facilities throughout Naval Support Activity Annapolis. There are two main chilled water plants (CHWPs). Both CHWPs utilize a closed loop system for operation. This system contains greater than 1.25 million gallons of chemically treated water maintained at 42 degrees Fahrenheit 24 hours per day, seven days per week. There is approximately 29,289 linear feet of piping within the closed loop consisting of approximately 29,289 linear feet of supply piping and approximately 29,289 linear feet of return piping. The first chiller plant is located at USNA-590A and is also known as the Rickover Plant or “Old 572U”. This plant has a total rated capacity of 5,000 tons. This capacity is spread across (2) 1,250-ton & (1) 2,500-ton centrifugal chillers. Two 1,250-ton chillers in 590A may be operated 24 hours per day, seven days per week. The 2,500-ton chiller in tandem with one 1,250-ton chiller is typically utilized when in summer/cooling season (usually MarchNovember). The second chiller plant is located at 597U and is also known as the LeJeune Plant or Chiller Plant II. This plant has a total rated capacity of 7,500 tons from three 2,500-ton centrifugal chillers. One 2,500-ton chiller in 597U may be