J- Facility Management
Updated
A PDF document (886 KB) attached to Base Operations Support Services For NSA Annapolis and US Naval Academy, Annapolis, Maryland, from the Department of the Navy.
File name: J-1501000 Facility Management.pdf
The full file is for paid members, or buy this bid alone.
Preview
SECTION J-1501000
FACILITY MANAGEMENT
ATTACHMENT
NUMBER
J-1501000-01
J-1501000-02
J-1501000-03
J-1501000-04
ATTACHMENT TITLE
DEFINITIONS AND ACRONYMS
REFERENCES AND TECHNICAL DOCUMENTS
ASSET TAGGING GUIDANCE
METER GROUP DESCRIPTIONS AND DIRECT CONDITION RATING
GUIDANCE
ATTACHMENT J-1501000-01
DEFINITIONS AND ACRONYMS
SEE SEPARATE ATTACHMENT J-0200000-01
ATTACHMENT J-1501000-02
REFERENCES AND TECHNICAL DOCUMENTS
SEE SEPARATE ATTACHMENT J-0200000-03
ATTACHMENT J-1501000-03
ASSET TAGGING GUIDANCE
INSTRUCTIONS:
LABELS SHALL BE 3”x2” AND PRINTED WITH TUFFLABELS OR EQUIVALENT.
HANDWRITTEN INFORMATION IS NOT ACCEPTABLE. TEXT SHALL BE TIMES NEW ROMAN
BOLD ALL UPPER CASE. ANY EXISTING ASSET LABEL NOT MEETNIG ALL REQUIREMENTS
WITHIN THIS ASSET TAGGING GUIDANCE SHALL BE REPLACED. KEY TO DIAGRAM ABOVE
IS AS FOLLOWS:
1.
2.
3.
4.
5.
6.
7.
TOP LINE TO BE “NAVFAC FACILITY ASSET” or “NAVFAC UTILITY ASSET” AS
APPLICABLE.
LOCATION OF THE ASSET AS FORMATTED IN NAVFAC MAXIMO.
BARCODE VERSION OF NAVFAC MAXIMO ASSET NUMBER.
TEXT VERSION OF NAVFAC MAXIMO ASSET NUMBER.
TEXT DESCRIPTION OF ASSET NAME AND CAPACITY/SIZE
QR CODE CONTAINING PIPE DELIMITED MAXIMO ATTRIBUTES INCLUDING:
a. LOCATION
b. ASSET NUMBER
c. ASSET TYPE
d. INSTALLATION DATE
e. MANUFACTURER
f. MODEL
g. SERIAL NUMBER
h. CLASSIFICATION & ATTRIBUTES FOR UTILITIES ASSETS PER J-1601000-10
DATE QR CODE IS GENERATED
ATTACHMENT J-1501000-04
METER GROUP DESCRIPTIONS AND DIRECT CONDITION RATING GUIDANCE
B2030410 - Overhead Doors
Meter & Description
Direct Condition Rating Guidance
CR-5200 - Record the
GREEN: Controls function properly
condition of the Controls AMBER: Controls need calibrating RED: Controls are damaged and/or not operational
CR-5250 - Record the
GREEN: Door has minimal damage and corrosion, is square and condition of the Door
securely fastened
AMBER: Door has noticeable damage and corrosion, may be slightly displaced, but does not affect door operation or safety RED: Door has significant damage and/or corrosion, noticeably displaced, and may be structurally unsound or affect door operation CR-5415 - Record the
GREEN: Guides/Stops/Rollers/Pulleys show no signs of wear or condition of the Guides
damage, and are properly secured and aligned
AMBER: Guides/Stops/Rollers/Pulleys show slight wear, and/or may be slightly loose or misaligned
RED: Guides/Stops/Rollers/Pulleys have noticeable damage or wear, and are insecurely fastened and/or misaligned
CR-5505 - Record the
GREEN: Motor operates properly, free of excessive noise/vibration, or