A

A

B

B

NEW FLUSH MTD.

NOTIFICATION APPLIANCE

NEW FLUSH MTD. PULL STATION

NOT TO SCALE

NOT TO SCALE

NEW SURFACE MTD.

NOTIFICATION APPLIANCE

NOT TO SCALE

NEW SURFACE MTD.
PULL STATION - MECH. RM.

NOT TO SCALE

NEW SURFACE MTD. PULL STATION

NOT TO SCALE

NEW SURFACE MTD.

DETECTOR - FINISH AREA

NOT TO SCALE

C

D

D

S

##

##

C

-

+

-

+

-

+

}
}

E

NEW SURFACE MTD.

DETECTOR - UNFINISH AREA

NOT TO SCALE

TYPICAL SPEAKERS/

STROBE WIRING DETAIL

NOT TO SCALE

TYPICAL ANNUNCIATOR DETAIL

NEW FLUSH MTD.

DETECTOR - LAY-IN CEILING

MISC WIRING DETAIL

10 NOT TO SCALE

NOT TO SCALE

TYPICAL PATCH @ GYP. BD. DETAIL

11 NOT TO SCALE

12 NOT TO SCALE

F

F

FINAL BID DOCUMENTS

CONSULTANTS:

PROJECT LEADER:

VETERANS AFFAIRS

MEDICAL CENTER

500 E VETERANS ST

TOMAH, WI 54660

Revisions:

Project Title

Project Number

FIRE ALARM

DETAILS

UPGRADE FIRE ALARM

SYSTEM DESIGN

676-22-110
Building Number

Approved: Project Director

Location

Drawing Number

Tomah, Wisconsin
Date

1021 N. Superior Ave, Unit 11
Tomah, Wisconsin 54660

Date

Drawing Title

Checked By: Drawn By:

APRIL 21, 2026

HFB

JCC

F501

Office of
Facilities
Management

F Ratings - 1, 2, 3 and 4 Hr (See Items 2 and 3)
T Ratings - 0, 1, 2, 3, and 4 Hr (See Item 3)

1A

A

S

DH

DH
S

A

1B

MAX PIPE OR

CONDUIT DIAM IN. F RATING T RATING

(MM)
HR
HR

1 (25)

1 OR 2 0+, 1 OR 2

1 (25)

3 OR 4

3 OR 4

4 (102)

1 OR 2

6 (152)

3 OR 4

12 (305)

1 OR 2

S
S

A

##

##

S

S

RTS/I

S

DS

##

##

A

MM

SECTION A-A

DS

S

B

B

C

TYPICAL FA SYSTEM RISER DETAIL

TYPICAL CONDUIT, PIPE, TUBE PASSING ANY WALL DETAIL

NOT TO SCALE

TYPICAL SEQUENCE OF INSTALLATION

NOT TO SCALE

C

NOT TO SCALE

D

D

TYPICAL ACCESS PANEL INSTALLATION DETAIL

NOT TO SCALE

TYPICAL EXTERIOR HORN/STROBE DETAIL

NOT TO SCALE

E

F

F

FINAL BID DOCUMENTS

CONSULTANTS:

PROJECT LEADER:

VETERANS AFFAIRS

MEDICAL CENTER

500 E VETERANS ST

TOMAH, WI 54660

Revisions:

Project Title

Project Number

FIRE ALARM

DETAILS

UPGRADE FIRE ALARM

SYSTEM DESIGN

676-22-110
Building Number

Approved: Project Director

Location

Drawing Number

Tomah, Wisconsin
Date

1021 N. Superior Ave, Unit 11
Tomah, Wisconsin 54660

Date

Drawing Title

Checked By: Drawn By:

APRIL 21, 2026

HFB

F502

JCC

Office of
Facilities
Management

A

A

B

B

C

C

D

D

E

F

F

FINAL BID DOCUMENTS

CONSULTANTS:

VETERANS AFFAIRS

MEDICAL CENTER

500 E VETERANS ST

TOMAH, WI 54660

Revisions:

Project Title

Project Number

FIRE ALARM B400 RISER

UPGRADE FIRE ALARM

DIAGRAM - BASEMENT, FIRST, & SYSTEM DESIGN

SECOND FLOORS - NEW WORK

Building Number

Approved: Project Director

Drawing Number

676-22-110
B400

Location

Tomah, Wisconsin
Date

1021 N. Superior Ave, Unit 11
Tomah, Wisconsin 54660

Date

Drawing Title

PROJECT LEADER:

Checked By: Drawn By:

APRIL 21, 2026