PERFORMANCE WORK STATEMENT
PEARL HARBOR NAVAL SHIPYARD AND INTERMIDIATE MAINTENANCE
FACILITY (PHNSY&IMF) CONTRACTOR SHIPBOARD TECHNICAL SUPPORT SERVICES FOR HIGH
PRESSURE AIR COMPRESSORS (HPAC) ONBOARD VIRGINIA CLASS SUBMARINE
1.0
Background:
1.1
This Performance Work Statement (PWS) describes tasks to be performed by awardee in support of a Virginia class Submarine during the Depot Modernization Period (DMP) at Pearl Harbor Shipyard, Hawaii. The awardee shall provide the required work required to generate the deliverables enumerated below.
2.0
Objectives/Scope:
2.1
OVERALL OBJECTIVE: The awardee, hereafter referred to as the Contractor, shall provide troubleshooting services and preventive maintenance on oil-free compressors (Model 5R5-75B) manufactured by RIX Industries as required in accordance with reference 1. The contract will support conduction of Satisfactory Operational Testing with Ship and Shipyard support. The contractor shall provide on-site technical support, troubleshooting and software upgrades where required. Maintenance and Operational Testing shall be within the contract duration allowed.
3.0
Performance Requirements:
3.1
The contractor shall provide technical support troubleshooting, software support, and technical support for repairs and testing of the No. 1 and No. 2 HPACs as required.
3.2
Travel: The Contractor shall perform travel to support the requirements of this PWS. For quote formulation and price evaluation purposes, the Contractor's firm-fixed-price proposal should target the maximum daily rate parameters established by the Joint Travel Regulations (JTR) and the coach-class definitions of FAR 31.205-46. For planning purposes, the basis for travel for the field service technicians shall originate from either the contractor’s business address or the technician’s primary place of residence (home station) directly to Honolulu, Hawaii (PHNSY&IMF) and return.
3.3
The Contractor’s work shall be governed by the completeness and quality of the work performed as summarized in 4.0, Table A, Service Delivery Summary.
3.4
All work shall be performed shipboard within designated machinery spaces at PHNSY&IMF. Specific onboard compartment access and technical reference manuals designated as Controlled Unclassified Information (CUI) will be provided to the Contractor by the Technical Point of Contact (TPOC) post-award.
3.5
References:
Title
NAVSEA TECHNICAL MANUAL S9550-CR-MMA-010 Rev
LAT, Air Compressor, High Pressure, 4500 psig Model 5R5-75B w/ Programmable Logic Controller.