Power Meters MSA Questions-Responses
Updated
A PDF document (175 KB) attached to Commercially Available Distance Measuring Equipment (DME) Power Meters, from the Federal Aviation Administration. Due Nov 23, 2026, 3:00 PM (UTC-5).
File name: Power Meters MSA Questions-Responses 11-10-2026.pdf
The full file is for paid members, or buy this bid alone.
Preview
Acquisition Sensitive – This document may contain information considered sensitive unclassified information (SUI) and would merit protection from unauthorized disclosure under 5 U.S.C, Section 552(b)(4). No information shall be released except as authorized by the Contracting Officer.
Questions/Responses
Market Survey Announcement FAA-DME-PWRMTR-MSA2026
Commercially Available Distance Measuring Equipment (DME) Power Meters
1. Are OEM-supported reseller responses acceptable, with deployment history and production capacity attributed to the OEM?
Response: Yes, provided that the reseller has received authorization from the OEM to submit a response.
2. What quantities, contract terms, option periods and ordering assumptions should vendors use for the ROM?
Response: This notice is not being issued for purpose of issuing a Request for Proposal. Please refer to Section 1 (Notice) of the MSA.
3. What delivery locations, lead times and shipment schedule should be assumed? Response: See response to question number 2.
4. Do the accuracy limits apply to the meter alone or the complete meter-and-sensor system?
Response: Accuracy applies to meter plus sensor system. 5.
Must the 65 dB range support peak measurements at ≥1.5 MHz bandwidth and must the display also operate through 55°C?
Response: The pulse spectrum is within 1 MHz; the requirement would be greater than or equal to 1 MHz. The 55°C requirement can be relaxed to a value of 40°C given the power meter is expected to be used in a controlled environment.
6. Is an adapter acceptable for the Type N female connection, and are computer-based displays acceptable?
Response: If it is an adapter alone (no additional cable) it would be acceptable. Regarding computer-based displays, it appears to be the current trend for power meters. However, the FAA IT would have to load it to installers computers, which may require additional coordination/requirements
1|Page
Acquisition Sensitive – This document may contain information considered sensitive unclassified information (SUI) and would merit protection from unauthorized disclosure under 5 U.S.C, Section 552(b)(4). No information shall be released except as authorized by the Contracting Officer.
7. Is a one or two channel power meter needed for this requirement? Response: At the present time, the FAA does not have a requirement for a dual power meter. For the response to this MSA, the single-channel, high-performance RF power meter is the minimum requirement.
The beginning of the document. Download the full file to read on.