PRE-SOL 695-22-121
Updated
A PDF document (831 KB) attached to Repair Bldg. 111 Concrete Facade 695-22-121 IFB, from the Department of Veterans Affairs.
File name: S02 - 36C25226B0039 PRE-SOL 695-22-121 9.23.2026.pdf
The full file is for paid members, or buy this bid alone.
Preview
Presolicitation Notice
SUBJECT* Repair Bldg. 111 Concrete Facade 695-22-121 IFB
GENERAL INFORMATION
CONTRACTING OFFICE’S ZIP CODE*
53214
SOLICITATION NUMBER*
36C25226B0039
RESPONSE DATE/TIME/ZONE
ARCHIVE
90 DAYS AFTER THE RESPONSE DATE
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
Z2DA
NAICS CODE*
236220
PLACE OF PERFORMANCE
Clement J. Zablocki VA Medical Center
500 W. National Avenue
Milwaukee WI
POSTAL CODE
53214-1473
COUNTRY
USA
CONTACT INFORMATION
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs
GLAC 69D
115 South 84th Street, Suite 101
POINT OF CONTACT*
Contracting Specialist
Zheily Ramos
[email protected]
1-414-844-4800
S02 - 36C25226B0039
Presolicitation Notice
Presolicitation Notice
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
S02 - 36C25226B0039
Presolicitation Notice
Presolicitation Notice
DESCRIPTION
Project:
Project Number:
Repair Building 111 Concrete Façade
695-22-121
Location:
Clement J. Zablocki VA Medical Center Milwaukee, WI
The Clement J. Zablocki VA Medical Center has a requirement to Repair Building 111 Concrete Façade Project 695-22-121 on the campus of the Milwaukee VA Medical Center. The project
location is Building 111 main hospital, exterior façade. This project will be the first of several phases to repair spalling concrete and cracks in the façade of Building 111, as well as to address vulnerabilities to water infiltration with the as-built exterior wall assembly. This project is
responsible to repair isolated repairs for cracks and spalls in the existing Precast Concrete panels, supplemental lateral anchorage at isolated panes, sealant replacement, and installation of flashing end dams and cavity closures at the interface between the precast concrete panels and brick masonry, which will necessitate removal and replacement of the brick masonry along the full height of the precast concrete panels. All existing caulk and joint sealant between the precast panels and brick masonry is to be removed. The full height of the precast panels extends from grade level
to the 11th floor roof level. This could include lift buckets, scaffolding and swing stages. Traditional Asbestos Abatement: Sample testing of these materials has documented it does contain a low level of asbestos. Note that the work on each façade shall be during regular shift time. The project magnitude price range is between $5,000,000 and $10,000,000. The North American Industry Classification Code (NAICS) for this procurement is 236220 with a size standard $45
The beginning of the document. Download the full file to read on.