Performance Work Statement | v1.0

PERFORMANCE WORK STATEMENT

FOR

OVERHEAD HOIST MAINTENANCE AND REPAIR

316 CES/ CEOES

10 September 2026

Performance Work Statement | v1.0

1. Description of Services

1.1 Scope

The Contractor shall furnish all labor, transportation, equipment, lifts, materials, tools, supplies, and supervision necessary to perform inspections, test, maintenance and repairs on the overhead hoist and associated equipment located on Joint Base Andrews (JBA) and Davidsonville MD. The Contractor’s maintenance and inspection program shall be based on original equipment manufacturer’s recommendations. Hoist inspections shall be an in-depth assessment, available for all brands, types, and sizes of overhead hoists, to help ensure regulatory compliance and assist with safety and reliability.

1.2 Overhead Hoist

The maintenance, repair, and inspection of these systems shall adhere and comply with applicable Occupational Safety and Health Administration, (OSHA), American Society of Mechanical Engineers (ASME), Department of the Air Force Manual 91-203 (DAFMAN), and American National Standards Institute (ANSI) regulations, in addition to manufacturer’s equipment specifications and recommendations (i.e., Operation and Maintenance Manuals). All work shall be performed by technicians who are qualified persons who possess formal training with deep working knowledge of the applicable standards to work on Overhead Hoist systems.

1.2.1 Preventative Maintenance (PM) and Repair Work
The purpose of this work is to prevent and correct equipment deficiencies, minimize breakdowns and service interruptions, extend systems’ life and maximize efficient operation. Mechanical and electrical safety checks shall be completed to ensure the safety of all systems. On an annual basis, a certified inspector shall inspect, test, adjust, and perform repairs in order to maintain equipment in a normal operating condition, as the manufacturer intended. Deficiencies found shall be corrected during scheduled maintenance, ensuring optimum, uninterrupted system operations. Hoist locations are identified in Appendix A. Inspections shall be coordinated with Contracting Officer Representative (COR) and facility managers at least 72 hours in advance of the inspection. The inspector shall document results of the annual inspections and make available to the COR within five (5) days, for the purpose of developing follow-on maintenance schedules as determined necessary. Estimated quantities for determining workload

The beginning of the document. Download the full file to read on.