Home / Brake Press Trainer – Freight and Delivery / Document

Q-A - Brake Presses

Updated

A PDF document (150 KB) attached to Brake Press Trainer – Freight and Delivery, from the Department of the Navy. Due Nov 10, 2026, 2:00 PM (UTC-5).

File name: N61340-27-SWSC-1 Q-A - Brake Presses.pdf

Download the full documentSee the bid

The full file is for paid members, or buy this bid alone.

Preview

Item

Question(s)

Government Response

Will Just Machinery Movers provide
loading equipment and personnel at
the pickup location, or must the
contractor provide all loading
services?

Just Machinery will load the two (2) brake presses, which are currently on skids, onto the successful contractor’s transport vehicle using Just Machinery’s equipment. Once loaded, the successful contractor will be responsible for securing the brake presses and providing all necessary equipment to safely transport, unload, and move them into Room 136 of Building 520.

Are photographs of both brake press
machines available, including lifting
points and their current condition?

Brake Press PowerPoint provided for photo reference.

Can the Government provide
photographs or measurements of the
Building 520 entrance, hallways,
door openings, and Room 136?

Loading Dock Door is 94", Door 2 - 83.5", Door - 3 85.5", Door 4 - 83.5", Door to Lab 83.5", Lowest point on the ventilation/ lights and electrical is 82". All middle columns can be removed from each door way.

Are there any floor-loading
restrictions or other limitations
affecting the movement of 6,800-lb
machines?

There are no known floor load limits, and no elevator.
Brake Press PowerPoint provided for photo reference.

Are forklifts or other materialhandling equipment available onsite, or must the contractor provide everything?

Just Machinery will load the two (2) brake presses, which are currently on skids, onto the successful contractor’s transport vehicle using Just Machinery’s equipment. Once loaded, the successful contractor will be responsible for securing the brake presses and providing all necessary equipment to safely transport, unload, and move them into Room 136 of Building 520.

Is final placement the full extent of
the requirement, or does the
contractor also need to anchor,
connect, or commission the
equipment?
Can the two hotshot drivers and
rigging subcontractor enter the
installation together using
coordinated visitor access?
Is there a designated staging and
unloading area suitable for two
hotshot trailers and a forklift?
Pickup site: Will Just Machinery
Movers load the machines onto the
contractor’s vehicle with their own
equipment? Or must the contractor
bring its own forklift and rigging to
the Woodstock site? Are the
machines currently crated, skidded,
or palletized?

No anchoring is required. The brake presses shall be placed in the

The beginning of the document. Download the full file to read on.