Q&A: N6893627Q0021
Scope
PM351 2nd FL Security Door Replacement
Is it possible to get photos of the existing door entry?
Existing Door Frame: Could the Government provide photographs or detailed drawings showing the existing door frame and surrounding conditions to support accurate pricing and installation planning? Door entry is for PM351 2nd FL RM2502 single Secure Door to be replaced. Refer to DoDM 5200.01-V3, February 24, 2012, Appendix to Enclosure 3 for guidance on secure door installation/requirements:
Steel door, 36” x 84”, 1 ¾” thick. Solid steel frame, heavy gauge (16 ga or 18 ga), 1 ½” wide, recessed back from face of concrete wall 2”. Drawings: The SOW mentions a drawing showing the conceptual design. It was not included in the posted files. Please provide the drawing and photos of the existing door, frame and hardware. Since there will be no site visit, can you provide existing-condition drawings, full measurements, or photographs available to assist with confirming compatibility with the specified replacement hardware? Frame: The materials list says to reuse the existing steel frame, while the demolition item says to remove the door, frame and hardware. Please confirm the frame stays. Yes, the frame can stay in place on the single door.
It is said the frame stays in place is this correct? Yes
Door configuration: Please confirm this is a pair of doors in a 6'0" x 8'0" opening, which leaf is active, the swing direction, and whether flush bolts, an astragal and a coordinator are required. Single door
Finish: Should the door be hollow metal, factory primed and field painted? If so, what color? Hollow metal, factory painted same color as existing door Access control and alarm: Will the existing reader cabling and access control system be reused? Who does the programming and the final alarm panel connection, the contractor or government security staff? PHYSEC
The Scope of Work calls to replace the existing CAC Reader with a new Hirsch 8336ABTR000 uTrust TS Scramble Prox read. Is there an existing power source to connect the new CAC reader? Yes
What is the STC rating? STC 42 minimum
Would you like an RF shielding applied to this opening? No
Are interface specifications or wiring diagrams available for the existing access control and intrusion detection systems? Unknown
Please also confirm that “LockSet” refers to the LKM10K / X-10 (Lockmasters / Kaba Mas) product line. Refer to the SOW
Does "LockSet" mean the Lockmasters LockOne LKM10K lock series named in the SOW? Refer to the SOW