Question
RFP Area
#
Requirement/
Paragraph #
Page #
Question
Government Response
Attachment 1 Statement of
Work
SOW CLIN 8
(E)(1)
Does this mean they require a quantity Yes.
of 4 liquid connection points to
withdraw liquid helium
simultaneously? We do not currently
have tanks with this configuration;
however, a bayonet adaptor might be
able to be configured to meet this
requirement.
Attachment 1 Statement of
Work
SOW CLIN 8
(E)(1)
(1) Is the 2”x4” dimension referring to (1) No, it’s referring to the diameter. 2” is the bayonet diameter and length, or
the inner diameter and 4” is the outer
valve stem?
diameter of the VJ line.
(2) Can they provide a clear description (2) (E) (1) outlines the needed connection of the cryogenic connection type, a
points.
drawing / specification of the
(3) No drawings or additional specifications
connection point for the container and are available.
flex hose? Our standard connection
uses a 2” diameter x 15” Length.
(3) Can NASA provide drawing of
bayonet connections?
Attachment 1 Statement of
Work
SOW CLIN 8
(E)(1)
Liquid isolation valve (V-1) has a CV See SOW, CLIN 8, (E) (1). of 23.5.
Attachment 1 Statement of
Work
SOW CLIN 8
(E)(1)
This seems to mean (1) liquid
withdrawal valve and (1) gas
withdrawal valve. (This is our
standard configuration).
Correct.
NASA Agency-wide Acquisition of Gaseous and Liquid Helium Questions and Responses to RFP
Question
RFP Area
#
Requirement/
Paragraph #
Page #
Question
Government Response
Attachment 1 Statement of
Work
SOW CLIN 8
(E)(4)
E-1 already describes the LHe
No. (E)(1) describes the LHe withdrawal
withdrawal connections as 2”x4”. Is
connection (2"x4"). (E)(4) describes the
this redundant to the description in E-1 diameter requirement of the outlet line. or is it intended to describe something
else?
Attachment 1 Statement of
Work
SOW CLIN 8
(E)(5)
E-1 already describes a “manual iso
Yes, the “manual iso valve Cv >=23.5” in
valve CV >=23.5”. Is this redundant to (E)(5) is redundant because (E)(1) identifies the description in E-1 or is it intended the requirements of the connections and to describe something else?
(E)(5) identifies the Cv requirement of the
Manual Outlet Isolation valve.
Terms and
Conditions
2.1.1 Notes:
All GHe
requirements
are Grade A
per MILPRF-27407E
This is not Govt Grade. This is grade
The beginning of the document. Download the full file to read on.