RESPONSE FORM FY27 Fracture Detection SSN
Updated
A Word document (29 KB) attached to Automated Ultrasound-Based, Super Intelligence (SI)-Enabled Fracture Detection, from the Office of Assistant Secretary for Preparedness and Response. Due Nov 18, 2026, 1:00 PM (UTC-5).
File name: RESPONSE FORM_ FY27 Fracture Detection SSN.docx
The full file is for paid members, or buy this bid alone.
Preview
SOURCES SOUGHT NOTICEAutomated Ultrasound-Based AI Enabled Fracture DetectionOfferor Technical Response Form Purpose. This form is intended to collect standardized market research information regarding technologies capable of detecting and characterizing clinically significant fractures using ultrasound. It is not a solicitation, request for proposal, or commitment to acquire any technology. Instructions to Offerors
Complete all applicable fields. If a capability is not available, enter “Not Available” or “Not Applicable” rather than leaving the field blank. Use space provided to summarize requested information. Attach additional, brief summaries when space provided is not sufficient. Identify whether each capability is demonstrated, under development, or proposed. Clearly distinguish measured performance from anticipated performance. Cite supporting evidence. Attach supporting publications, test reports, regulatory materials, product literature, or other documentation as appropriate. For diagnostic performance, provide the study population, comparator, sample size, fracture distribution, operator characteristics, and statistical confidence intervals whenever available. Where information is proprietary or controlled, identify the restriction and provide a non-proprietary summary sufficient for market research. Offeror and Product Identification
Field
Offeror Response
Company / Organization Name
Commercial Product / Technology Name
Product Model / Version
Company Website
Primary Point of Contact / Title
Email / Telephone
DUNS / UEI (if applicable)
Place(s) of Manufacture
U.S. Manufacturing Capability
Current Product Status
Executive Technology Summary
Provide a concise (≤500 words) description of the technology, intended use, principal differentiators, current maturity, and anticipated use in trauma/mass-casualty settings.
1. DISPLAY AND Diagnostic Capability
Capability / Requirement
Status
Detects long-bone fractures
☐ Demonstrated ☐ Development ☐ Planned ☐ N/A
Detects wrist fractures
☐ Demonstrated ☐ Development ☐ Planned ☐ N/A
Detects ankle fractures
☐ Demonstrated ☐ Development ☐ Planned ☐ N/A
Other clinically significant fracture locations (specify) ☐ Demonstrated ☐ Development ☐ Planned ☐ N/A
AI-assisted interpretation
☐ On device ☐ Cloud ☐ Both ☐ None
Sensitivity
☐ Measured ☐ Estimated ☐ Not available
Specificity
☐ Measured ☐ Estimated ☐ Not available
PPV / NPV, if available
The beginning of the document. Download the full file to read on.