Action Code: Sources Sought Notice
Subject: Thomaston Lake Dam, Gate House Roof Repairs, Thomaston, CT Sources Sought Number: W912WJ-27-X-1CY2
NACIS Code: 238160
Response date: December 11, 2026
Place of Performance:
US Army Corps of Engineers, New England District
696 Virginia Road
Concord, MA
01742-2751 US
The U.S. Army Corps of Engineers, New England District is issuing this Sources Sought Announcement for Construction Services for the repairs to the Gate House Roof at Thomaston Lake Dam in Thomaston, Connecticut. This announcement is to determine interest, availability and capability of 8(a), HUBZone, Service-Disabled Veteran-Owned, Women-Owned and Small Business concerns for this project. The NAICS code for this procurement is 238160 with a size standard of $19M. The project is planned to be issued in the Spring of 2027 with construction to take place in the Summer of 2027. The estimated construction cost is between $350,000 - $500,000.
Thomaston Lake Dam is situated on the Naugatuck River and is a part of a network of flood control dams and local protection projects built by the U.S. Army Corps of Engineers in the Upper Connecticut River Basin. The construction was completed in 1960.
The dam is located between Hill Road (to the east) and James H Darcey Memorial Highway (to the west). The dam consists of a rockfill earth gravity dam with stone slope protection 2,000-feet long and 137-feet high and a 435-foot-wide uncontrolled spillway.
The work of this project involves removing the existing EPDM roof, thermal insulation and all associated components and replace with new thermal insulation and roof membrane system. The existing roof has a parapet wall around the perimeter which an existing scupper exists. The existing scupper will be required to be enlarged. The work also includes installing a new roof hatch and fall protection railing system. The existing lightning protection system will be removed and replaced with a new lightning protection system. The roof is approximately 35 feet above the service bridge deck which only accesses one side of the gate house tower. Work pertaining to the scupper will require special fall protection requirements as this side of the gate house tower is over water at a height greater than 45 feet. The contractor will need to comply and submit all required USACE safety submittals for this project. Interested firms should submit a capabilities package to include the following: business classification (i.e.