Statement of Requirement
Industrial Walk-In Oven
The Government requires one commercial, electric industrial walk-in oven to support high-temperature drying and curing processes. The oven shall be capable of providing controlled, uniform heating for the intended work products and shall meet the following minimum requirements.

1. General Requirements

•

The oven shall be an electric industrial walk-in oven designed for drying and curing operations.

•

The oven shall use a dual or combination recirculating-air system to ensure temperature uniformity throughout the effective work area.

•

The oven shall be fully assembled, wired, factory set up, and tested before shipment.

•

The oven shall include a minimum one-year manufacturer’s warranty from the date of shipment.

2. Physical Configuration

•

Minimum effective work area: 7 feet wide by 7 feet high by 10 feet long.

•

Maximum external dimensions: 9 feet 8 inches wide by 12 feet 5 inches high by 11 feet 6 inches long.

•

The oven shall be sized to pass through an existing overhead door measuring 8 feet wide by 10 feet high.

•

The oven shall include dual insulated access doors mounted on heavy-duty hinges.

•

The access doors shall include a secure latch mechanism, high-temperature seals, and a proof-of-closure safety limit switch.

•

The oven floor shall be zero-clearance and constructed of a minimum 3/16-inch steel plate or equivalent durable material.

•

The oven controls shall be in an exterior wall-mounted control panel.

•

Electrical and control components shall be housed in NEMA 12 or NEMA 4 enclosures, as appropriate for the operating environment.

3. Airflow and Ventilation

•

Heated air shall be distributed through the oven ceiling using perforated slots, diffusers, or equivalent adjustable louvers.

•

Return airflow shall be routed through sidewall returns, internal plenums, or an equivalent configuration that supports uniform airflow.

•

The oven shall include a 6-inch-diameter gravity vent.

•

The oven shall include an exhaust vent with a damper.

•

The Government will provide the required exterior wall opening for the gravity vent.

4. Electrical and Thermal Performance

•

The oven shall operate on 480-volt, three-phase, 60-Hz electrical power.

•

The oven electrical load shall not exceed 35 amps and shall be compatible with a recommended 50-amp circuit breaker.

•

The oven shall achieve a maximum operating temperature of at least 500 degrees Fahrenheit.

•

The oven shall support controlled low-temperature curing beginning at 60 degrees Fahrenheit, or the lowest controllable temperature achievable above