STATEMENT OF WORK
Diesel UHP Trailer 20K PSI/20 GPM
1. SCOPE.
1.1. Portsmouth Naval Shipyard (PNSY) is seeking to lease a portable (trailer mounted), self-contained, diesel motor driven 20,000 PSI, 20 GPM Ultra High Pressure (UHP) water jet system with support services (Startup/commissioning, training, preventative maintenance and weekly equipment inspections) for use at Portsmouth Naval Shipyard, Kittery, Maine. The required components of the system, their performance parameters and the required support services are detailed in the Statement of Work. (SOW). Unless otherwise stated, the contractor shall furnish the UHP system, including all labor, supervision, tools, materials, equipment and other items and services that are necessary to perform as described within this SOW.
2. APPLICABLE DOCUMENTS.
2.1. Issues of Publications. The following documents, which are in effect on the date of the solicitation is issued, are a part of this specification to the extent applicable, or as specified herein. Within the specification, they shall be referred to by their basic designation only.
2.1.1. Government Furnished
2.1.1.1. Corporate Lifting and Handling Manual
2.1.2. Nongovernment Furnished
2.1.2.1. N/A
2.2. Order of precedence. In the event of conflict between the SOW and the references cited above, the text of this SOW shall take precedence. Nothing in this SOW, however, shall supersede applicable laws or regulations unless a specific exemption has been obtained.
3. REQUIREMENTS.
3.1. Component List.
3.1.1. UHP Water Jet required components.
PIECE
NO.
PC-01
PC-02
PC-03
PC-04
PC-05
QTY.
NAME OF PART
Trailer mounted UHP waterblast unit
Hose, 50ft, 20K WP
Burst Disc 24K PSI
Burst Disc 28K PSI
E-stop and cabling
PARA NO.
3.2
3.5
3.4
3.4
3.2
3.2. UHP Water Jet System Requirements.
3.2.1. Diesel Powered
3.2.2. Operating Pressure: 0-20,000 PSI
3.2.3. Flow Rate: 20 GPM
3.2.4. The pump shall be powered by a single diesel engine with a fuel tank sized to run the equipment. 3.2.5. Diesel tanks must be either of double wall construction meeting UL-142 requirements or have approved integrated secondary containment or external berm style containment of 110% of the tank capacity.
3.2.6. UHP water jet system shall be suitable for outdoor operation with an ambient operating temperature range of -10°F to 110°F.
3.2.7. UHP equipment shall have an operator control panel, which provides the following features: 3.2.7.1. Warning displays will indicate and the pump will shut down if automatic sensors indicate low
The beginning of the document. Download the full file to read on.