STATEMENT OF WORK
FALL ARREST SYSTEM INSPECTION
Fairchild Air Force Base, Washington
DESCRIPTION OF WORK. Contractor shall perform annual inspections of the fall protection systems located in building 2050 hangars No. 1, 2, 3, & 4 located at Fairchild AFB, Washington. Building 2050 is located in a controlled area. Escorts will be provided by the government as coordinated in advance to perform services. Non-U.S. citizen workers are prohibited from accessing the controlled area. The annual inspection shall be performed in accordance with all federal, state, local regulations and manufacturer recommendations. The inspection is necessary to ensure continued compliance with OSHA Regulations and manufacturer recommendations. The contractor shall provide an 85-foot lift to access the system.
As a minimum the inspection shall consist of the following actions: A hands on inspection of all components of the installed system Visually verify all end terminations
Tighten all lock nuts to the required torque
Inspect for presence of cotter pins where appropriate Check for damage to all components including cable along its entire length, intermediate brackets and end termination
Inspect intermediate brackets for excessive deformation Perform minor repairs as needed
Photo document any in-depth repairs that may be required Inspect user equipment supplied with the original system or replacement of same make and model, including harnesses and lanyards.
Perform all other actions required to comply with OSHA and/or manufacturer’s inspection requirements.
The inspection will be limited to the engineered system components installed by Evan Corporation or manufactured by Capital Safety Group and installed by others. At the completion of the inspection, the contractor shall issue a written report attesting to the condition of the system and its conformance with OSHA Regulations. The report shall include an estimate for any repairs that may be required.
OPERATIONS SECURITY (OPSEC) REQUIREMENTS. The contractor will protect critical and/or sensitive information from disclosure. The DoD contractor will: 1. Be familiar with their organization’s critical information. When publicly posting or publishing workrelated information that potentially contains critical or sensitive information airmen are encouraged to solicit the advice of their immediate supervisor, security office and/or OPSEC Program Manager/Coordinator.