STATEMENT OF WORK

FOR
GA-VGMS-33528 Upgrade

SCOPE:

This Statement of Work defines the requirements for providing hardware, software development, and on-site engineering services to upgrade and enhance the existing vacuum system. The contractor shall provide the specified components, perform necessary software modifications, and validate the system's functionality as detailed herein.

HARDWARE REQUIREMENTS: The contractor shall provide the following hardware, software, and services

VGMS Power Supply Box (V-G-A-0005): One (1) unit designed to work with a VTI VGMS and feature a 10-channel multiplexor interface. Note: The 10-channel card is to be supplied by the customer. Main interface cable is not included. Interface Cable for Multiplexor (E-C-EC-A-0005): Ten (10) units for connecting a GP 390411 to the multiplexor interface. 15-25 PSIG Rupture Disc (M-P-PO-0135): One (1) UHV-compatible, all-stainless-steel rupture disc with a 1/4" Female VCR-Type Connection. Inficon Ion Gauge Controller (V-G-IG-0016): One (1) Inficon VGC083x series controller. Note: Cables are not included. Convection Gauge Cable (V-G-IG-A-0014): One (1) 10 ft. long cable for the Inficon VGC083x controller. Power Supply for Inficon VGC083x (E-C-PS-0046): One (1) 24V, 221W AC/DC power supply with an included power cord. Half-Width Rack Rail Controller Panel (E-E-IC-A-0052): One (1) panel for mounting the Inficon VGC083B controller. Bakeable Ion Gauge Cable (V-G-IG-A-0016): One (1) 10 ft. long bakeable cable for the Inficon VGC083B controller.

PERFORMANCE REQUIREMENTS:

Continuity of performance: All normal performance characteristics of the GA-VGMS-33528 shall be maintained or exceeded after the upgrade is performed.

FUNCTIONAL REQUIREMENTS:

Continuity of functionality: All normal functionality of the GA-VGMS-33528 shall be maintained or exceeded after upgrade is performed.

CONTROLLER REQUIREMENTS:

Controller: Upgrade shall use existing controllers.
Operating System and Software: All software must run under Microsoft Windows 10 LTSC 64 bit operating system or Windows 11 LTSC, whichever is available.

SOFTWARE/FIRMWARE REQUIREMENTS:

Software Identification: If applicable, all software used in conjunction with instrument shall be identified by Name, Version, and Date; to be displayed upon startup or located in an “About” menu.

Software Warranty: The contractor shall warrant that the product meets this purchase description, is free from defects in design and operation, and will perform to stated specifications within this purchase description for the length of the warranty.

The beginning of the document. Download the full file to read on.