Section C - Description/Specifications/Statement of Work

GENERAL SPECIFICATIONS

0403 SERV NEW Nelson Dr Fuel Tank Removal
Final – 06/30/2026
1.1

SCOPE OF CONTRACT

A.

This project includes the removal of two existing steel underground fuel storage tanks at the Nelson Drive housing complex on the Bridger-Teton National Forest; two 300-gallon steel underground fuel storage tanks associated with two neighboring residential dwellings. This includes cleanup and disposal of any contaminated soils. Contractor shall field verify all new and existing conditions affecting the work of this contract before ordering products.

B.

The following project scope items are described herein and in further detail in the Specification Sections.
1.

1.2
A.

Base Bid Item No. 1: Mobilization in accordance with Specification Section 012000 Mobilization. Jackson Ranger District is located at 340 Cache St, Jackson, WY 83001.
2.
Base Bid Item No. 2: Tank Removal – This item includes removal and disposal of two (2) underground heating oil storage tanks, anticipated to be approximately 300gallons. The two tanks service a duplex, one (1) tank for each housing unit. Work requires the potential removal of uncontaminated soil. Removal also includes all piping and appurtenances, backfilling the excavation and native soil surface restoration to existing conditions. Item also includes sampling the soil around the tank and decommissioning the tank to Wyoming Department of Environmental Quality (WYDEQ) requirements and standards.
3.
Base Bid Item No. 3: Selective Demolition – Removal of Concrete – Contractor shall protect housing structures and surrounding site conditions during removal. This item also includes removal of grassed areas necessary to remove the underground heating oil storage tanks
4.
Base Bid Item No 4: Sidewalk, Portland Cement Concrete, 4-inch thickness – Contractor shall restore demolished concrete from removing the two (2) underground heating oil storage tanks. This item also includes replacing approximately 300 square feet (SF) concrete at an additional dwelling. 5.
Option Item No. 1: Removal and disposal of contaminated soil per cubic yard (CY). See also Specification Section 312000 Earth Moving. Contaminated soil must be removed and disposed in a State Authorized disposal facility for contaminated soil. Not to exceed 20 CY.
Option Line Item may be awarded at time of base line items, or up to 30 days.

PROJECT LOCATION

The project is located in the Jackson Ranger District of the Bridger-Teton National Forest,