Procurement of CX-41 Flexim Emerson Flowmeter

1.0 Background

The gaseous nitrogen (GN2) meter station used by United Launch Alliance (ULA) at Space Launch Complex 41 is in need of an overhaul due to parts obsolescence, corrosion, and design flaws. A Flexim flow meter, consisting of the following items, is needed to replace old obsolete flow meter and measure flow rate during operations for billing purposes. The procurement also includes several items that are considered included subparts from the vendor and are identified below.

2.0 Requirements

The following items are necessary to ensure parts are available for ULA equipment to support Atlas and Vulcan systems, ensuring successful launch. Items must be purchased new. Line items with a dot (.) correspond to the above listed line item and are included with the preceding line item.
Item No.

8.1

Part Number

DE7-G731GP-F2NNN-2ST4MR.CS2.MN4.TT2.IS2/FVA




731761-00
721110-4
801037-9
990760-10

TRD-GSP-NF2 N-NNTl-004

Descrip on
Transmi er, G731
G731
[G) FLUXUS for the measurement of: gases
[731) Type: 731
[GP] General purpose
[F2] explosion protec on:
FM Class I, II, Ill Div. 2
[NI Non-intrinsically safe
[NN] No addi onal cer ficate
[2) Measuring channels : 2
[STI Housing: stainless steel
[4] Power supply: 11...32 V DC
[MR) Modbus RTU Outputs
[CS2) 2 x current output, switchable,
ac ve/passive, 0/4 ... 20 mA
[MN4) 4 x digital output (open collector) 8.2 V
NAMUR (DIN EN 60947-5-6), status, pulse,
frequency 0.002 ... 10 kHz Inputs
[TT2) 2 x temperature input Ptl00/1000
[IS2) 2 x ac ve/passive current input
[FVA) Advanced Meter Verifica on
!Full func onality only with FluxDiagfull version
-Opera ng instruc on
-Transmi er-Fixa on (op on)
-Data transmission kit
-Supplements
Clamp-on transducer,
Transducer cal ibra on with aperture calibra on

6 measuring points, including calibra on

Quan ty

2 (each)

These are
included in
line item #8

Procurement of CX-41 Flexim Emerson Flowmeter
cer ficate (factory calibra on, no accredited
report)
[GI For the measurement of: gases
[SI Typ: Shear wave
[Pl Transducer frequency P-2 MHz
Inner pipe diameter (recommended): 0.79 ... 2.0
in inner pipe diameter (extended): 0.59 ... 2.4 in
[N] Normal temperature
[F2] explosion protec on: FM Class I, II, Ill Div. 2
[NN] No addi onal cer ficate
[Tl] Connec on system: stripped cable ends
[004] Cable length: 13
9.1

The beginning of the document. Download the full file to read on.