Home / Bureau of Prisons / Metal Window and Door Manufacturing / Notice

FCC Lompoc B&F Project 25Z6AXX Emergency Fire Escape Doors

Updated

Solicitation from the Federal Prison System / Bureau of Prisons, for work in California. Due Nov 16, 2026, 1:00 PM (UTC-8), 10 days left.

Be among the first to see new Metal Window and Door Manufacturing contracts
Only new notices that match, once a day.
Solicitation number15B61727Q00000002
AgencyFederal Prison System / Bureau of Prisons
OfficeFcc Lompoc
Notice typeSolicitation
Set-asideSmall business
Trade (NAICS)Metal Window and Door Manufacturing (332321)
Product or service code1290
Place of performanceCalifornia
PostedNov 5, 2026
Response deadlineNov 16, 2026, 1:00 PM (UTC-8) (10 days left)
Add the deadline toGoogle Calendar · Apple / Outlook (.ics)
Official notice
Send to a teammate

Bid documents (3)

Paid members download every document from this page, or buy this bid alone.

Federal prevailing wage rates for this place: California Davis-Bacon and SCA wage determinations.

Description

Statement of work / request for quote a. Introduction:

  1. The Federal Bureau of Prisons (FBOP), FCC Lompoc, 3901 Klein Blvd., Lompoc, CA 93436, is seeking quotes from qualified vendors for the supply and delivery of nine (9) complete fire escape door assemblies, including doors, frames, and all required hardware. The doors are for a prison facility application and must meet all relevant local, state, and federal fire and life safety codes.
  2. "Equal or Better" Product Substitution: Proposals must meet or exceed the specified product quality. If an alternative product or component is offered, the vendor must submit all technical documentation, certifications, and test results for consideration.
  3. Government's Right of Final Technical Acceptance: The government retains the sole and final authority to determine technical acceptance for all submitted products, based on the provided documentation and compliance with stated standards.

B. SCOPE OF WORK: 1. The vendor shall provide all materials as specified below. All components must be new, U.L. Listed or labeled by a recognized testing agency acceptable to the Authority Having Jurisdiction (AHJ) and conform to the standards referenced herein.

C. TECHNICAL SPECIFICATIONS: TABLE 1: COMPONENTS: All units shall be identical unless otherwise noted. Component Requirement Quantity 9 Complete Door Assemblies Door Size 36" wide x 80" high x 2" thick Door Material Hollow Metal Door, minimum 12 Gauge galvanneal steel Core Ribbed and Insulated (mineral core for fire rating is acceptable/preferred) Fire Rating Rating must be compatible with the wall's fire resistance rating, typically 75% of the wall's rating.

See required fire rating for correctional facilities on Table 2 Handing 4 Left Hand Outswing, 5 Right Hand Outswing. Frame Material Minimum 12 Gauge galvanneal steel, fire-rated and labeled Frame Type Knock-down (KD) for drywall/unit masonry or welded for masonry. Frames are to be prepared for 80 series lock, keyed 2 sides strike, surface pull on both sides and prepped for PA closer.

Finish Factory primed for field painting TABLE 2: FIRE RATING: The complete door assembly (door, frame, and all hardware) shall be 90 minutes fire rated. This rating must be compatible with the fire-resistance rating of the specific wall assembly in which the door will be installed, as dictated by the building's fire safety plan and local code requirements. Category Requirement Description Applicable Standards & Agencies Listing & Labeling All components must be listed and labeled by a recognized third-party testing agency acceptable to the Authority Having Jurisdiction (AHJ).

Underwriters Laboratories (UL), Intertek (WH), Factory Mutual (FM) Testing Standard Assemblies shall be tested under positive pressure conditions. NFPA 252, ANSI/UL 10C Labeling Visibility A permanent, legible fire rating label must be affixed to both the door and the frame and remain visible after installation for inspection purposes. N/A Code Compliance Vendor must confirm that all components, when installed as an assembly, comply with relevant building and safety codes for correctional facilities (Group I-3 Occupancies, IBC).

NFPA 80 (Standard for Fire Doors and Other Opening Protectives) International Building Code (IBC) TABLE 3: HARDWARE SPECIFICATIONS: All hardware must be "listed" or "labeled" for use on a fire-rated assembly, compatible with the specified fire rating, and factory-prepped for ANSI/BHMA Grade 1 standards. Item Requirement Quantity per Door Notes Hinges Heavy-duty steel ball bearing hinges, UL Listed 3 Exit Device Panic Hardware/Fire Exit Hardware (rim or mortise type) self-latching 1 set Must be a crossbar or touch bar device, operable with an applied force of 15 lbs or less.

Locking Must be openable from the egress side at all times without special knowledge or tools. Keyed access from the exterior is permitted. 1 set 80 series lock, keyed 2 sides strike, surface pull on both sides and prepped for PA closer.

Door Closer Heavy-duty, adjustable, surface-mounted, UL Listed 1 unit Must be self-closing and ensure positive latching. Seals Smoke and draft control gasketing/seals 1 set Required for a complete smoke-rated assembly. Threshold [Specify if required, e.g., 1/2" beveled aluminum, non-combustible] 1 unit (if required) D. Code and standard requirements:

  1. All supplied materials and the complete assembly must comply with the latest editions of the following codes and standards (or local equivalents as adopted by the AHJ): NFPA 80: Standard for Fire Doors and Other Opening Protectives NFPA 101: Life Safety Code International Building Code (IBC) International Fire Code (IFC) OSHA requirements for exit routes UL 10C or NFPA 252: Standard for positive pressure fire testing of door assemblies UL 1784: Standard for Air Leakage Tests of Door Assemblies (if smoke rating is required)
  2. Vendors must confirm that all components, when installed as an assembly, will bear a permanent, legible label from a recognized third-party testing agency (e.g., UL, Intertek/WH, FM). E. SUBMISSION REQUIREMENTS: 1. Itemized pricing for doors, frames, hardware, and any included accessories. 2. Proposed lead time for manufacturing and delivery to FCC Lompoc
  3. Confirmation of compliance with all referenced codes and standards.
  4. Cut sheets/product data for all proposed items.

F. DELIVERY OF MATERIALS:

  1. Deliveries shipped directly to FCC LOMPOC can only be received between 7:30 a.m. and 2:00 p.m., Monday through Friday, excluding Federal Holidays.
  2. POC: Mr. Fernando Pena, BOP Engineering Technician, [email protected], or 805-735-2771
  3. FBOP will be responsible for receiving or signing deliveries.
  4. FCC LOMPOC will provide resources for loading and unloading materials or equipment upon arrival.

Contracting contact

As published on the official notice. Ask questions in writing and before any questions deadline the notice sets.

Is your business small enough?

For NAICS 332321, a business counts as small if it has no more than 750 employees (SBA size standard). This notice is set aside, so only businesses under that size, or in the named program, can bid. SBA table, current as of Oct 15, 2026.

Companies that win this kind of work

Federal contractors paid for metal window and door manufacturing work, who also hold Bureau of Prisons contracts (last 12 months): possible competitors, or partners to team with.

About the buyer

The Federal Bureau of Prisons awarded $3.1 billion in contracts in the last 12 months; its biggest suppliers were Naphcare LLC, Mckesson Corporation and Motorola Solutions, Inc.. See what Bureau of Prisons is buying now.

Who can bid: Small Business set-aside

Total and partial small business set-asides are open to any business under the SBA size standard for the notice's NAICS code.

All open Small Business set-asides.

Metal Window and Door Manufacturing contracts right now

There are 11 open government contract opportunities in this trade (NAICS 332321), 6 posted in the last 7 days; 64% are set aside for small businesses. The agencies buying the most are Defense Logistics Agency, Department of the Navy and Federal Prison System / Bureau of Prisons. Most of the work with a stated place is in Washington, California and Maryland. A notice in this trade gives a median of 14 days from posting to deadline; this one gives 11 days.

All open metal window and door manufacturing contracts

Coming up in this trade

Planned contracts from the agencies' procurement forecasts, often months before a solicitation. Plans can change.

Bushland Building 1 Perimeter Insulation Fenestration and HVAC Project
Agricultural Research Service
Acquisition Planning · Award FY 2027 · $2M - $4.9M · Firm Fixed Price
Rehabilitate Hatchery Building, Replace Doors
Department of the Interior
Acquisition Planning · Award FY 2026 · Below $150K · To Be Determined
New Garage Door for South Raceway Building
Department of the Interior
Acquisition Planning · Award FY 2026 · Below $150K · To Be Determined

Recent awards in this trade

From the award notices agencies publish.

Similar open metal window and door manufacturing bids

Garage Doors
Department of the Army
Due Dec 16, 2026, 1:00 PM (UTC-6) · 40 days left
Solicitation · Small business · Posted Nov 5, 2026
Sole Source to Jered LLC - Hanger Door Replacement Parts
Department of the Navy
Due Nov 12, 2026, 1:00 PM (UTC-8) · 6 days left
Solicitation · Posted Nov 4, 2026
Pharmacy Window Boxes
Department of Veterans Affairs
Due Nov 16, 2026, 10:00 AM (UTC-5) · 10 days left
Solicitation · Tacoma, WA · Posted Nov 4, 2026
Alternative Gate Arm Solutions used at Border Crossings
US Customs and Border Protection
Due Dec 3, 2026, 12:00 PM (UTC-5) · 27 days left
Sources Sought · Posted Nov 3, 2026
Fixture, Lighting
Defense Logistics Agency
Due Nov 13, 2026 · 7 days left
Solicitation · Posted Nov 2, 2026
Hatch
Department of the Navy
Due Nov 18, 2026, 12:00 AM (UTC-8) · 12 days left
Solicitation · Bremerton, WA · Posted Oct 29, 2026