Annual REC Solar Panel Maintenance
Updated
Solicitation from the Department of Veterans Affairs, for work in Los Angeles. Due Dec 7, 2026, 10:00 AM (UTC-8), 26 days left.
| Title as posted | Z1MG--Annual REC Solar Panel Maintenance |
|---|---|
| Solicitation number | 36C26227Q0119 |
| Agency | Department of Veterans Affairs |
| Office | 262-Network Contract Office 22 (36C262) |
| Notice type | Solicitation |
| Set-aside | Service-disabled veteran-owned |
| Trade (NAICS) | Electrical Contractors and Other Wiring Installation Contractors (238210) |
| Product or service code | Z1MG |
| Place of performance | Los Angeles |
| Posted | Nov 10, 2026 |
| Response deadline | Dec 7, 2026, 10:00 AM (UTC-8) (26 days left) |
| Add the deadline to | Google Calendar · Apple / Outlook (.ics) |
Bid documents (5)
- Bid document 81 KB
- Annual REC Solar Panel Maintenance Enclosure 1 49 KB
- Annual REC Solar Panel Maintenance Enclosure 2 58 KB
- WEST LA GENERAL SOLAR MAP 7.5 MB
- West LA Campus Map 2.6 MB
Paid members download every document from this page, or buy this bid alone.
Wage rates for this bid
- Service Contract Act wage determination 2015-5613 California Counties of Los Angeles
Description
2 | Page 1. This is a combined synopsis/solicitation for commercial services/items prepared in accordance with the format in FAR Subpart 12.2 in conjunction with FAR Part 13, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a separate written solicitation will not be issued.
1.a. Project Title: Annual REC Solar Panel Maintenance 1.b. Description: VA Greater Los Angeles Healthcare System located at 11301 Wilshire Blvd; Los Angeles CA 90073 is seeking a contractor to provide preventive maintenance services on VA owned REC solar panels and solar inverters at the VA West Los Angeles Campus, 11301 Wilshire Blvd., Los Angeles, CA 90073. 1.c.
Project Location: VA Greater Los Angeles Healthcare System, 11301 Wilshire Blvd, Los Angeles, CA 90073 1.d. Solicitation Type - Number: Request for Quotes (RFQ) - 36C26227Q0119. 1.e. Set Aside: This solicitation is issued as an SDVOSB set aside.
1.f. Applicable NAICS code: 238210 Electrical Contractors and Other Wiring Installation Contractors. 1.g.
Small Business Size Standard: $19 million 1.h. Type of Contract: Firm Fixed Price 1.i. Period of Performance: Base year plus 4 option years 1.j.
Wage Determination applicable to this project: SCA WD 2015-5613 revision 34 1.k. Questions regarding the solicitation should be submitted via email no later than 2pm PST Monday, November 30th, 2026, to [email protected] 1.l. Job walk will be conducted at 11am on Monday, November 23rd, 2026.
Participants will meet with Ross Manoukian and Moses Dominguez in Bldg. 63 at the VA Greater Los Angeles Medical Center, 11301 Wilshire Blvd, Los Angeles, CA 90073. A location map is attached to this solicitation. Please reach out to Moses Dominguez at 310-904-4009 if you need to locate the meeting point.
Please email [email protected] to indicate intent to participate 1.m. Company info and quote should be in the attached Enclosure 1 form. All other forms of offer will not be accepted.
Your enclosure form and capabilities statement/experience should be sent in one email with 2 separate email attachments, or it will not be accepted 2. Statement of Work BACKGROUND. The purpose of this contract is to have a contractor provide training, maintenance, repair, inspection and cleaning of the VA WLA Solar PV inverters and arrays.
Contractor shall provide all maintenance and services. The Contractor shall furnish all parts, labor, equipment, qualified personnel, qualified supervision, and transportation necessary. SCOPE.
Contractor shall provide services as follows: Preventative Maintenance Service Description Service Frequency General Inspections: Visual inspection for signs of damage, overall wear and tear, module breakage, loose conduit, broken straps, etc. Sample check torque marks and tighten loose connections 2x/yr Electrical Inspections and Maintenance: Perform Check integrity of weather resistance (seals, hubs and weather stripping) Check electrical equipment housing for signs of corrosion Perform Infrared scans, as needed In Contract Year 1 only, four single-technician, one-day dispatches for labor only corrective maintenance as needed 1x/yr Inverter Inspections and Maintenance: Check integrity of weather resistance (seals, hubs and weather stripping) Check inverter housing for signs of corrosion Clean inverter air vents and heat sink clean filters Replace inverter filters in AE Solaron model 250, 333, 500 and Satcon model 75, 250 central inverters Perform Infrared scans, as needed 1x/yr Array Washing: Includes normally expected soiling conditions.
Heavy cleaning, such as excessive soiling, debris removal, bird droppings and soot, not to exceed 10% of total array 2x/yr & Additional Upon request Carport Solar Panel Washing and Cleaning: Carport Solar Panel Washing & Cleaning to occur on a weekend. 2x/yr Vegetation Control: Remove or mow weeds and grasses located in accessible areas under the array. Turn off solar panels and ensure solar panels and inverters are not damaged.
1x/yr Contractor shall provide a completed maintenance checklist within 3 weeks following each visit, which includes a list of issues discovered, resolution, and accompanying photos as appropriate. Carport solar panel washing & cleaning needs to be performed on the weekends. Solar Panel Locations: Solar Array Location Solar Monitoring Inverters myPVData 333 KW Solaron Inverter Site 3- West of Building 304 Employee Parking Lot myPVData Two 333 KW Solaron Inverter Site 4- West of Building 402 Employee Parking Lot myPVData One 333 KW and one 250KW Solaron Inverters Site 5- Ground Mount North of Helipad myPVData 250 KW Solaron Inverter Building 500 Rooftop myPVData 250 KW Satcon Inverter Buildings 510 & 511 Rooftops myPVData 75 KW Satcon Inverter Building 213 Rooftop Draker (2) SMA SB 9000TL & (2) SMA SB 8000TL Building 218 Rooftop Draker (5) SMA SB 9000TL Building 222 Rooftop Draker (2) SMA SB 9000TL & (2) SMA SB 8000TL Building 401 Rooftop Draker (2) Refusol 016K & (2) Refusol 012K Building 304 Rooftop Draker (2) Refusol 020K & (2) Refusol 016K Building 508 Rooftop Draker (6) SMA SB7000TL Parking Lot 12 & 299 Draker (1) 250 KW Solaron Parking Lot 49 Draker (1) Refusol 024K, (4) Refusol 020K, & (2) Refusol 012K South of Heliport Ground Mount Draker 500 KW Solaron Inverter The Government will provide the following: Site access and a safe working environment.
Facility contacts to provide real time information about site conditions (power outage, active construction, etc.). Coordination and closing the parking area for the washing and maintenance activities during the weekends. Contractor can use VA West LA outdoor water source but may have to provide means to transport water as needed and required if water source is not close to solar arrays.
Contractor to verify water sources. Field work will be performed during local business hours unless otherwise agreed by the solar contractor and the VA COR The Con
The description continues in the official notice.
Contracting contact
- Ositadima Ndubizu · Contracting Officer · [email protected] · (562) 766-2252
As published on the official notice. Ask questions in writing and before any questions deadline the notice sets.
Is your business small enough?
For NAICS 238210, a business counts as small if it has no more than $19.0 million in average annual receipts (SBA size standard). This notice is set aside, so only businesses under that size, or in the named program, can bid. SBA table, current as of Oct 15, 2026.
Companies that win this kind of work
Federal contractors paid for electrical contractors and other wiring installation contractors work, who also hold VA contracts (last 12 months): possible competitors, or partners to team with.
- J & J Mechanical And Construction Group LLC $19.2 million in this trade
- OEG Inc $19.1 million in this trade
- KAR Contracting LLC $12.9 million in this trade
- Skytek LLC $6.7 million in this trade
- Iron Mike Construction LLC $5.7 million in this trade
About the buyer
The Department of Veterans Affairs awarded $83.7 billion in contracts in the last 12 months; its biggest suppliers were Optum Public Sector Solutions, Inc., Mckesson Corporation and Triwest Healthcare Alliance Corp. See what VA is buying now.
Who can bid: Service-Disabled Veteran-Owned (SDVOSB) set-aside
SDVOSB set-asides are for small businesses owned and controlled by service-disabled veterans, certified by the SBA.
How to get certified: SDVOSB certification guide. All open Service-Disabled Veteran-Owned (SDVOSB) set-asides.
Electrical Contractors and Other Wiring Installation Contractors contracts right now
There are 58 open government contract opportunities in this trade (NAICS 238210), 35 posted in the last 7 days; 74% are set aside for small businesses. The agencies buying the most are Department of Veterans Affairs, Department of the Army and Department of the Air Force. Most of the work with a stated place is in Colorado, Virginia and Florida. A notice in this trade gives a median of 20 days from posting to deadline; this one gives 27 days.
All open electrical contractors and other wiring installation contractors contracts
Coming up in this trade
Planned contracts from the agencies' procurement forecasts, often months before a solicitation. Plans can change.
Recent awards in this trade
- Itm4G LLC $690,266 · Department of the Army · Nov 10, 2026
- RK SERVICE LLC 3800 XANTHIA STREET Denver CO $17,591 · Departmental Offices · Nov 9, 2026
- F & C Group JV LLC $2.2 million · Department of Veterans Affairs · Oct 23, 2026
- Dash Technologies Inc $133,375 · Department of Veterans Affairs · Oct 6, 2026
- HSQ Tech, Inc. $790,929 · Department of the Air Force · Sep 25, 2026
From the award notices agencies publish.