Print Form
UFC 1-300-08
30 JUNE 2004
Const. Contract No: N40085-15-D-0815
APPENDIX D
BUILDING INFORMATION CHECKLIST
Use Appendix D as a checklist of required information to be entered into the real property database. Provide this information for each Real Property Facility listed on the DD Form 1354 in a format that allows easy data entry into the real property system. Normally this information is provided by the A/E electronically, often in XML format or GIS compatible format.
BUILDING IDENTIFICATION for this 5-Part CHECKLIST
Facility
Number
Bldg 575
Number
of Floors
Building Name
Bldg 575 MOTOR T
Gross SF
67,228
1. Building Dimensions and Construction Materials
Building Outside
Dimensions
Length (LF)
Main Building
EXISTING
Wings
N/A
Offsets
N/A
Basement
N/A
Attic
N/A
Porches, covered
N/A
Roof
N/A
Foundation
N/A
Width (LF)
EXISTING
Other Building Data
Feet
Ceiling Height Main Bldg.
EXISTING
Ceiling Height Basement
N/A
Door Height
7'-0"
Door Width
3'-0" VARIES
Code
Fire Rating Code
TYPE IIB, F, S, AND B OCCUPANCY
Construction Materials
Type
Principal Structural Material
CMU
Secondary Structural Material
STEEL FRAME
Exterior Wall Material
BRICK, EIFS
Interior Wall Material
DRYWALL, TILE, CMU
Floor Surface Material
CONCRETE, TILE, CARPET
Sub-Floor Material
N/A
D-1
Net SF
64,500
UFC 1-300-08
30 JUNE 2004
Additional Construction Materials
Type
Pile or Foundation Material
Foundation Form
Foundation
EXISTING
EXISTING
Roof Type
Roof Support
EXISTING
Roof Deck
EXISTING
Roof Surface
EXISTING
Roof Material
STANDING SEAM METAL
3-PLY MOD BIT
Construction Materials
(Pavements)
Type
Surface Course Materials
CONCRETE, ASPHALT
Base Course Materials
GRAVEL
2. Utility Connections, Information and Fuel Data
Utility
Connections
Number of
Pipes
Water
EXISTING
Gas
EXISTING
Sewer Pipe
EXISTING
Storm Sewer Pipe
N/A
Steam
N/A
Diameter of
each pipe
Capacity of
all inlet pipes
Available or
Connected?
(Yes/No)
Condensate
Communications
4"
Energy
Type
System
YES
Source
Location
Fuel
Description
Air Circulation
Heating
GAS
METER
GAS
FORCED AIR
Air Conditioning
ELECTRIC
MAIN PANEL
N/A
FORCED AIR
Hot Water
GAS
METER
GAS
Steam
N/A
Electrical
ELECTRIC
METER
N/A
Electric
Phase
Wire
Size
Voltage
Connected
Load - AMPS
PANEL MPD
3 PHASE
480/277VAC
4 WIRE
600A
PANEL 4PD1
3 PHASE
4 WIRE
400A
T1
3 PHASE
480-208/120V
4 WIRE
5KVA
D-2
Connected
Load - KVA
UFC 1-300-08
30 JUNE 2004
3. Building Systems
Nomenclature
Amount
of UM
UM
Fire Protection System
Closed Head Auto Sprinkler
HD
TBD
Open Head Deluge System
HD
N/A
Auto Fire Detection System
HD
YES
Manual Fire Alarm System
The beginning of the document. Download the full file to read on.