A

B

DESIGN PACKAGE DEVELOPED BY:

DATA CENTER AND INFRASTRUCTURE ENGINEERING

GENERIC EXTRA SMALL (~780FT2) DATA CENTER DESIGN PACKAGE

FOR MAIN COMPUTER ROOMS (MCRS)

AND OTHER

CAMPUS SUPPORT CENTERS (CSCS)

A

B

C

C

D

D

DATE

SHEET:

SHEET TITLE

ISSUE DATE:

PRINT DATE:

DOC VERSION No:

OF

TITLE

Jun 25, 2021

Sep 21, 2021

1.0

KEVIN GRZELKA, CTDC

MICHAEL JULIAN, RCDD

KELLY BATES, DCIE

CHECKED BY:

Generic Extra Small Data Center Design Package 1.vsd

DESCRIPTION

DESIGNED BY:

FILE:

DRAWING No:

ISSUE:

MARK

GENERIC EXTRA SMALL DATA

CENTER DESIGN PACKAGE

FOR MCRS AND

OTHER CSCS

PROJECT:

ENTERPRISE DATA CENTER AND

INFRASTRUCTURE ENGINEERING

IT Operations and Services
Solution Delivery

Department of Veterans Affairs

A

B

C

D

C

M

J

#

OR

#
TYP

DETAIL NUMBER

TYPICAL THROUGHOUT THIS

SHEET

6 FT WIDE, 8 FT HIGH DOOR, NO CENTER MULLION, FIRE

RESISTANT TO ¾ HOUR OR MORE PER AHJ

3 FT WIDE, 8 FT HIGH DOOR, FIRE RESISTANT TO ¾ HOUR OR

MORE PER AHJ

4'X 8' AC GRADE ¾” TRADE SIZE PLYWOOD BACKBOARD

PAINTED HIGH-GLOSS WHITE WITH TWO COATS OF FIRE

RESISTANT PAINT FOR SERVICE PROVIDER / SECURITY /

VIDEO / ET CETERA

NEW WALL

DEMO WALL

ARCHITECTURAL

MODULAR UPS CABINET (POWER MODULES, BATTERIES,

POWER PANELS)

POWER BUSWAY WITH METERED HEADEND FOR B SIDE

POWER DISTRIBUTION

POWER BUSWAY WITH METERED HEADEND FOR A SIDE

POWER DISTRIBUTION

LED LIGHTING

FIXED CAMERA, PAN/TILT/ZOOM, PASSIVE INFRARED

CAMERA - DUAL TECHNOLOGY”

PIV ENABLED TWO-FACTOR AUTHENTICATION KEYPAD

CEILING MOUNTED MOTION SENSOR (LOCATIONS AS

REQUIRED FOR FULL ROOM COVERAGE)

MOTION SENSOR LIGHT SWITCH

TYPICAL UNSWITCHED 110 VOLT, 20 AMP DUPLEX

CONVENIENCE OUTLET

POWER BUSWAY TAP WITH DUAL BREAKER AND TWO 3'

DROP CORDS WITH L21-20R FOR HIGH DENSITY CABINETS

POWER BUSWAY TAP WITH SINGLE BREAKER 3' DROP

CORD WITH L21-20R FOR STANDARD-DENSITY CABINETS

POWER JUNCTION BOX FOR 60A CONNECTION

OVERHEAD POWER DROP CORD WITH L21-30 RECEPTACLE

OVERHEAD POWER DROP CORD WITH L21-20 RECEPTACLE

ELECTRICAL SERVICE PANEL

#
TYP

#

LEGEND

WIRE MESH CABLE TRAY SIZE COMMENSURATE WITH

REQUIREMENTS

BONDING BUSBAR

DETAIL NUMBER

ELECTRICAL

SLEEVE WITH BUSHING FIRESTOP AND INNERDUCT FOR

FIBER

SLEEVE OR CONDUIT WITH BUSHING FIRESTOP AND

INNERDUCT FOR FIBER

ADDITIONAL SPLIT PACKAGE AIR CONDITIONER OR LARGER

UNIT TO REJECT HEAT FROM ADDITIONAL RACKS (17,000

BTU PER TELECOMMUNICATIONS RACK)

AC

REQUIRED CLEARANCE AROUND CRACS

COMPUTER ROOM AIR CONDITIONER (SEE COMPUTATIONAL

FLUID DYNAMICS REPORT FOR SIZING)

RETURN AIR DUCT

COLD AISLE CONTAINMENT (PVC CURTAIN)

STANDARD 25% OPEN PERFORATED FLOOR TILE

MECHANICAL

TELECOMMUNICATIONS CABINET, 7' HIGH, 45U, 40"X48"

(NOMINAL), SQUARE PUNCHED RAIL, SINGLE

The beginning of the document. Download the full file to read on.