NITROUS OXIDE,USP

PHYSICAL FORM GAS SUPPLIED AMOUNT 250.000 GALLONS NITROUS OXIDE USP SZ D CYLINDER 250 GL SUPPLEMENTARY FEATURES D-DAY ITEM FOR DOD UNIT OF ISSUE - EA(EACH)

.

SHALL BE IN ACCORDANCE WITH MIL-N-37996 DATED

24 DECEMBER 1985, EXCEPT AS FOLLOWS:

.
PARA. 2.1.1, UNDER "SPECIFICATIONS FEDERAL",

DELETE ALL REFERENCE TO RR-C-901/3; UNDER

"SPECIFICATIONS MILITARY" ADD THE FOLLOWING:

"MIL-L-10547 - LINER, CASE, AND SHEET, OVERWRAP,
. WATER VAPORPROOF OR WATERPROOF,
. FLEXIBLE";

UNDER "STANDARDS MILITARY" DELETE ALL REFERENCE

TO MIL-STD-105, MIL-STD-129 AND MIL-STD-1186.

ADD THE FOLLOWING NEW CATEGORY:

.

"OTHER MILITARY

. "MEDICAL MARKING STANDARD NO. 1"

.

PARA. 2.1.2, UNDER PUBLICATIONS, DELETE

"TM-38-250" AND SUBSTITUTE "DLAI 4145.3".
.

PARA. 2.2, UNDER "AMERICAN NATIONAL STANDARDS

INSTITUTE (ANSI), ADD THE FOLLOWING:

. "ANSI/ASQ Z1.4 - SAMPLING PROCEDURES AND

. TABLES FOR INSPECTION BY

. ATTRIBUTES"

DELETE PARENTHETICAL NOTE ENTIRELY AND SUBSTITUTE:

."(APPLICATION FOR COPIES SHOULD BE ADDRESSED TO

THE AMERICAN NATIONAL STANDARDS INSTITUTE, 11 WEST

42ND STREET, NEW YORK, NY 10036-8002.)"

.

ALSO IN PARA. 2.2, ADD THE FOLLOWING:

.

. "ASTM INTERNATIONAL

. "D 1974 - STANDARD PRACTICE FOR METHODS OF

. CLOSING, SEALING, AND REINFORCING

. FIBERBOARD SHIPPING BOXES

. "D 5118 - STANDARD PRACTICE FOR FABRICATION OF

. FIBERBOARD SHIPPING BOXES

. "(APPLICATION FOR COPIES SHOULD BE ADDRESSED TO

ASTM INTERNATIONAL, 100 BARR HARBOR DRIVE, WEST

CONSHOHOCKEN, PA 19428-2959, WWW.ASTM.ORG.)"

.

PARA. 3.2.2, SECOND LINE, DELETE "AND FEDERAL

SPECIFICATION SHEET RR-C-901/3" ENTIRELY. ADD THE

FOLLOWING SENTENCE: "THE FOLLOWING EXCEPTIONS ARE

APPLICABLE TO RR-C-901:"

.

ADD THE FOLLOWING NEW SUBPARAGRAPHS:

.
"3.2.2.1, IN RR-C-901, PARA. 3.1 DESCRIPTION,

THIRD LINE AFTER 'FROM 4130X STEEL' ADD 'OR

INTERMEDIATE MANGANESE STEEL'.
.

"3.2.2.2, IN RR-C-901, PARA. 3.2.2

NONSHATTERABILITY, FOURTH LINE AND SIXTH LINE,

AFTER '4130X STEEL' ADD 'OR INTERMEDIATE MANGANESE

STEEL'.
.
"3.2.2.3, IN RR-C-901, PARA. 3.10 COMPONENTS,

LAST SENTENCE, DELETE "AND D". ADD 'ALL SIZE D

MEDICAL CYLINDERS SHALL BE PROVIDED WITH A NECK

FLANGE AND A CAP IN ACCORDANCE WITH THE REQUIREMENTS

OF PARAS. 3.10.1 AND 3.10.2.' "

.

DELETE PARA. 3.2.3.1 ENTIRELY AND SUBSTITUTE:

"3.2.3.1 WHEREVER POSSIBLE ON D SIZE CYLINDERS,

THE TARE WEIGHT AND SERVICE PRESSURE SHALL BE MARKED

IN BOTH ENGLISH AND METRIC UNITS. METRIC MARKINGS

ARE MANDATORY ON ALL OTHER SIZES. THE FILL DATE

SHALL BE STENCILED ON THE CYLINDER. EACH CYLINDER

The beginning of the document. Download the full file to read on.