OXYGEN, TECHNICAL
MEDICAL GRADE OXYGEN USP COMPRESSED GAS IN A CYLINDER; SIZE H, 1650 GALLON, INLET SIZE 6, CGA 540 VALVE; SUPPLIED WITH VALVE CAP AND NECK FLANGE; COMPLIES WITH UNITED STATES PHARMACOPOEDIA (USP).
SHALL BE IN ACCORDANCE WITH MIL-O-37997 DATED
18 DECEMBER 1985 EXCEPT AS FOLLOWS:
.
PARA. 2.1.1., UNDER "STANDARDS MILITARY" DELETE
ALL REFERENCE TO RR-C-901/3.
.
PARA. 2.1.1, UNDER "STANDARDS MILITARY" DELETE
ALL REFERENCE TO MIL-STD-105 AND MIL-STD-129.
ADD THE FOLLOWING:
"OTHER MILITARY
. "MEDICAL MARKING STANDARD NO. 1"
.
PARA. 2.1.2, UNDER PUBLICATIONS, DELETE
"TM-38-250" AND SUBSTITUTE "DLAI 4145.3".
.
UNDER 2.2, ADD THE FOLLOWING:
.
"ASTM INTERNATIONAL
. "D 1974 - STANDARD PRACTICE FOR METHODS OF
. CLOSING, SEALING AND REINFORCING
. FIBERBOARD BOXES
. "D 5118 - STANDARD PRACTICE FOR FABRICATION
. OF FIBERBOARD SHIPPING BOXES
"(APPLICATION FOR COPIES SHOULD BE ADDRESSED TO
ASTM INTERNATIONAL, 100 BARR HARBOR DRIVE, WEST
CONSHOHOCKEN, PA 19428-2959, WWW.ASTM.ORG.)
.
"AMERICAN NATIONAL STANDARDS INSTITUTE
. "ANSI/ASQ Z1.4 - SAMPLING PROCEDURES AND
. TABLES FOR INSPECTION BY
. ATTRIBUTES
"(APPLICATION FOR COPIES SHOULD BE ADDRESSED TO
THE AMERICAN NATIONAL STANDARDS INSTITUTE, 11
WEST 42ND STREET, NEW YORK, NY 10036-8002.)"
.
PARA. 3.2.1 DELETE "AND FEDERAL SPECIFICATION
SHEET RR-901/3".
.
RENUMBER EXISTING PARA. 3.2.3 TO 3.2.3.1 AND
EXISTING PARA. 3.2.3.1 TO 3.2.3.2 AND ADD THE
FOLLOWING NEW PARA. 3.2.3:
"3.2.3 MARKING. CYLINDERS SHALL BE PERMANENTLY
MARKED BY STAMPING ON THE SHOULDER OF EACH
CYLINDER. THE MARKINGS SHALL BE NOT LESS THAN
3/16 INCH HIGH FOR CYLINDERS LESS THAN 6 INCHES
IN OUTSIDE DIAMETER AND NOT LESS THAN 3/8 INCH
HIGH FOR CYLINDERS MORE THAN 6 INCHES IN OUTSIDE
DIAMETER. IN ADDITION, EACH CYLINDER SHALL BE
PERMANENTLY MARKED WITH THE CLEAN AIR STAR IN
ACCORDANCE WITH 49 CFR, PARA. 173.34."
.
IN RENUMBERED PARA. 3.2.3.1 SPECIAL MARKINGS,
DELETE "DELETE FIRST SENTENCE ("CYLINDERS...
RR-C-901/3.") LINE 5, DELETE "POTENCY - 60
MONTHS" AND SUBSTITUTE "FILL DATE"; LINE 8,
DELETE "EXPIRATION DATE" AND SUBSTITUTE "FILL
DATE".
.
NOTE: THERE SHALL BE NO EXPIRATION DATING
ANYWHERE ON THE CYLINDER. THIS INCLUDES ANY
LABEL ON THE CYLINDER.
.
PARA. 3.3.1.1 DELETE THE WORD "EACH" IN LINES 3
AND 5 AND REPLACE WITH THE WORD "THE".
.
PARA 3.3.11 DELETE "MIL-V-2/42" AND SUBSTITUTE
"MIL-DTL-2/42" AND DELETE "MIL-V-2/41" AND
SUBSTITUTE "MIL-DTL-2/41".
.
IN PARA 4.3 INSPECTION DELETE MIL-STD-105 AND
SUBSTITUTE "ANSI/ASQ Z1.4".