Home / Base Cape Cod & Harwich Housing Refuse & Recycling / Document

Attachment 5: Performance Requirements Summary

Updated

A PDF document (69 KB) attached to Base Cape Cod & Harwich Housing Refuse & Recycling, from the US Coast Guard. Due Nov 24, 2026, 12:00 PM (UTC-5).

File name: Attachment 5 - Performance Requirements Summary.pdf

Download the full documentSee the bid

The full file is for paid members, or buy this bid alone.

Preview

PERFORMANCE WORK STATEMENT (PWS)

REFUSE AND RECYCLING SERVICES

USCG BASE CAPE COD, MASSACHUSETTS

USCG HOUSING HARWICH MASSACHUSETTS

ATTACHMENT 5

Performance Requirement Summary
1. The government expects the contractor to perform all services required in the Performance Work Statement (PWS) at an acceptable level. Whenever the Government learns of substandard performance, either through periodic inspections, direct observation, customer complaints, or any other mechanism, the preferred course of action will be discussions with the Contractor to inform the contractor of a problem. Discussions should e ectively prevent recurrences of substandard performance. However, this Performance Requirement Summary (PRS) provides an alternative mechanism by which the Government’s payment to the Contractor may be reduced in the event of substandard performance.
2. Criteria for acceptable and unacceptable levels of performance are as follows: Certain tasks will be considered critical to the Government’s performance of its duty to its personnel as well as for safety, well-being, health, and welfare. Because of this, the Government has listed certain tasks as critical and must be completed properly every time as scheduled. Coast Guard Base Cape Cod identified the below listed items as critical contract requirements:
a. On Time Delivery of On-Call Containers (PWS 5.1.1, 5.1.2) b. Contractor-Furnished Containers (PWS 5.2.1, 5.2.2)
c. Container Construction and Maintenance (PWS 5.2.5, 5.2.6, 5.3.4) The standards for the above items must not exceed two (2) defects per month because of this all-other tasks per the contract may have to four (4) defects and will still be considered acceptable. However, any complaints received thereafter will cause the services to be unacceptable for the month.
3. The Government’s primary quality assurance procedures are based on validated customer complaints and periodic inspections by the Contracting O icer’s Representative (COR). One complaint will be counted for each reported and verified unacceptable performance of service (as listed in the PWS). Thus, if one person complains that the six (6) cubic yard container outside the galley was not emptied during a one-week period and that the immediate vicinity of any containers was not cleaned during collection, this would count as two complaints, one for each unsatisfactory

PERFORMANCE WORK STATEMENT (PWS)

REFUSE AND RECYCLING SERVICES

USCG BASE CAPE COD, MASSACHUSETTS

USCG HOUSING HARWICH MASSACHUSETTS

The beginning of the document. Download the full file to read on.

Other documents in this bid