Exhibit 09. Seismic Offer Forms
Updated
A PDF document (1.7 MB) attached to VHA seeking 20,250 RSF for a Community Based Outreach Clinic in Twin Falls, ID, from the Department of Veterans Affairs. Due Nov 10, 2026, 4:00 PM (UTC-8).
File name: Exhibit 09. Seismic Offer Forms.pdf
The full file is for paid members, or buy this bid alone.
Preview
RLP No. 36C24W26R0017
Exhibit 09
RLP OFFER ATTACHMENT - SEISMIC OFFER FORMS
Instructions for Offeror:
Forms A through D are pre-award submittals. Depending upon the form, either the Offeror or the Offeror’s engineer shall complete and sign the form to confirm seismic compliance with RP 8. When the engineer fills out a form, he or she is also required to stamp it. The Offeror’s engineer shall represent whether the Building meets RP 8 standards, using Form A for Benchmark Buildings or Form B for other existing buildings. If the engineer’s certification indicates that the Building does not meet RP 8 standards, the Offeror shall agree to retrofit the building to meet the standards, using Form C, Part 1. Offerors providing new construction shall commit to a design code, using Form C, Part 2. Offerors may represent that their building meets an exemption criteria, using Form D. Forms E and F are post-award submittals. They only apply when the Offeror has agreed to either retrofit an existing building (use Form E) or is constructing a new building (use Form F). Prior to the Government accepting leased space, the Lessor’s engineer shall complete, stamp, and sign the appropriate representation. The forms must include the supporting documentation stated in the RLP and Lease. Below is a detailed explanation of each of the forms.
SEISMIC FORM A - CERTIFICATE OF SEISMIC COMPLIANCE BENCHMARK BUILDING
A benchmark building is one that was designed and built or retrofitted in accordance with structural provisions that are considered to provide acceptable life-safety protection. RP 8, Section 1.3, Table 1-1 shows the construction codes that qualify a building as a Benchmark Building. If a building qualifies, no additional hazards need be considered. If the seismicity of a region has changed since the benchmark dates listed in the table, the building must be evaluated in accordance with the now current or greater seismicity of the region to be compliant with the RP 8 Standards.
SEISMIC FORM B - CERTIFICATE OF SEISMIC COMPLIANCE EXISTING BUILDING
The engineer shall evaluate the building to determine compliance with the Life Safety Performance Level. He or she shall use RP 8 Chapter 3 and ASCE/SEI 31 to determine compliance. The evaluation must include the appropriate Structural, Nonstructural, and Geologic Site Hazard and Foundation Checklists with backup calculations.
SEISMIC FORM C – BUILDING RETROFIT OR NEW CONSTRUCTION PRE-AWARD
COMMITMENT
Part 1 only applies to planned retrofit of an existing building. The Offeror shall identify the
The beginning of the document. Download the full file to read on.
Other documents in this bid
- TWIN FALLS Global Request for Lease Proposal
- Exhibit 01. Draft Lease No
- Exhibit 02. Agency Requirements
- Exhibit 02a. Program for Design PFD
- Exhibit 02a1. Project Room Contents List-PRCL
- Exhibit 02a2. Appendix A2 - Lease Design Narrative LDN
- Exhibit 02a4. VA CBOC IT Systems Specifications v05.23
- Exhibit 02b. Janitorial Services
- Exhibit 03. Security Requirements - Facility Security Level II
- Exhibit 04. 3516 Solicitation Provisions Feb. 2025
- Exhibit 05. 3517B General Clauses (Apr. 2026)
- Exhibit 08. Prelease FPLS Evaluation Form 12000 Part A and Part B