Exhibit B Hilo-Vet Center Statement of Work ASR-A New Replacing
Updated
A PDF document (1.6 MB) attached to Hawaii - HILO Vet Center - Relocation, from the Department of Veterans Affairs. Due Oct 30, 2026, 5:00 PM (UTC-5).
File name: Exhibit B_Hilo-Vet Center SOW ASR-A New Replacing.pdf
The full file is for paid members, or buy this bid alone.
Preview
RCS CAPITAL ASSET MANAGEMENT 09.18.2025
READJUSTMENT COUNSELING SERVICE - VET CENTER
STATEMENT OF WORK - AGENCY SPECIFIC REQUIREMENTS
The Department of Veterans Affairs is interested in leasing (contiguous) clinical space for a Vet Center. The Lessor shall provide all materials, parts, and labor to complete the space and room requirements. The Vet Center Agency Specific Requirements will be used in conjunction with the standards and specifications found in the Request for Lease Proposal and the GSA Global Lease. If any conflict between standards or regulatory framework is found, the offeror must use the higher standard and follow the more stringent regulation. The Lease shall be Fully Serviced with the following services paid for/provided by the Lessor through the annual rent. 1. Utilities.
2. Janitorial.
3. Basic Cable to include local channels in the Waiting Area (Lobby) and three Group Rooms. 4. Guest Business High-Speed Internet Wi-Fi.
5. Security and CCTV System monitoring and maintenance to include software/hardware updates provided by the Lessor and paid through the annual rent. 6. Security System tested quarterly by the Lessor; a copy of the report sent to VA. A. SPACE REQUIREMENTS.
1.
10RCS/STA703 VET CENTER
Space design to provide maximum co-location of staff offices and group rooms. Refer to RLP Exhibit, Space Requirements for additional details required for this location.
Page 1 | 18
B. ROOM REQUIREMENTS
Room #
1. EXTERIOR
Electric. a.
Mobile Vet Center (MVC). One (1) Exterior 50 AMP outlet with dedicated circuit for the (MVC) enclosed with weatherproof and locking RV Power Outlet Box; location determined by the VA.
Safety. b. Cameras. Exterior cameras provide unobstructed monitoring of pedestrian entrances, exits, and government vehicles.
10RCS/STA703 VET CENTER
Page 2 | 18
Other. c.
Flagpole.
- Ability to display an 4x6 American Flag and a 3x5 POW flag underneath, near building main entrance. - Illuminated during the hours of darkness.
- Minimum Height 20 feet.
- Stainless steel or aluminum in material as per VA Standard Specification section 10 75 00.
Door. a.
Power Assisted Front Entrance Door or Automatic Single Slide Automatic Door System with Safety Sensors and Hardware.
2. ENTRANCE
Key Control Access. b.
c.
Other. d.
10RCS/STA703 VET CENTER
Access Controlled Door with electronic pin lever or electronic card access locking mechanism. Video Intercom system to allow VA staff to view, communicate, and open the door remotely before allowing access to space.
The beginning of the document. Download the full file to read on.