NH100 REPLACE ENGINE CONTROL UNITS ON 3 GENERATORS
NAVAL MEDICAL CENTER CAMP LEJEUNE
AT
CAMP LEJEUNE, NORTH CAROLINA 28533-0006
1. GENERAL INTENTION: It is the declared and acknowledged intention of this solicitation to obtain the supervision, expertise, labor, materials, and equipment to replace 3 Engine Control Units on Emergency Generators at NH100 Naval Hospital to restore compliance to emergency electrical distribution system. 2. LOCATION: Building NH100, Camp Lejeune in North Carolina. 3. CURRENT SITUATION: The Emergency Power Supply System (EPSS), three (3) generators, controllers, and emergency power supply distribution system are in various stages of failure but currently crippled with immediate action required. One generator is in manual configuration with a temporary Engine Control Unit (ECU) to keep it online and the other two generators locked out due to ECU failure. The ECUs are not repairable and must be replaced. Hospital Operations are, and will, continue to operate in a reduced capacity until Emergency Power capabilities are restored. One generator CANNOT maintain mission requirements of code compliant healthcare delivery. Upon unmitigated or uncontrolled loss of electrical utility power, the sole generator will immediately move into load shedding to only support what it can until it runs to failure. This is a high-risk scenario.
Current state is that all three generator ECUs must be replaced and the ECU replacements that Detroit Deisel provides require the accompanying onboard controllers, custom fabricated wiring harnesses and associated seals, pulse-controlled fuel injectors, voltage regulators, and associated controls to be replaced in conjunction with the ECU replacement in order for them to work together as originally designed. Once installed, these components must be programmed to be integrated into the existing PLC controllers in paralleling switchgear to ensure they synchronize and coordinate power loads and connectivity to the electrical distribution system under current control parameters. The contractor shall replace the ECUs on all three EPSS generators and all associated appurtenances in order to restore automatic EPSS operations. Once all components are installed, the contractor shall hire a verified Commissioning Agent and perform a complete generator system acceptance test in accordance with National Fire Protection Association NFPA 110. The NFPA 110 acceptance test shall be witnessed by DHA and the facility manager and final acceptance will be determined by DHA. Upon completion,
The beginning of the document. Download the full file to read on.