Preview

Enclosure (02)

Naval Surface Warfare Center Carderock Division
Radiation Technology Group – Code 632

IM-272A/WDQ Performance and Testing Specification

Developed by: M. Spierenburg --- NSWCCD
Reviewed by: M. Farruggia --- ISEA

Revision 03

14 May 2019

Enclosure (02)

SCOPE

1.1. Scope. This specification covers the performance and testing requirements for the IM-272A/WDQ Radiacmeter, Air Monitor for Radioactive Particles, hereinafter referred to as the radiacmeter. 2.

APPLICABLE DOCUMENTS

2.1. Government documents.
2.1.1. Specifications, standards, and handbooks. Unless otherwise specified, the following specifications, standards, and handbooks of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DoDISS) specified in the solicitation form a part of this specification to the extent specified herein.

SPECIFICATIONS - MILITARY

MIL-S-901D

Shock Tests. H. I. (High Impact) Shipboard Machinery, Equipment, and Systems, Requirements for

MIL-STD-461G Department of Defense Interface Standard: Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment

MIL-STD-167-1A

Department of Defense Test Method, Mechanical Vibrations of Shipboard Equipment (Type I – Environmental and Type II - Internally Excited) MIL-STD-1399 Interface Standard for Shipboard Systems, Section 300B, Electric Power, Alternating Current

DOD-STD-1399

Department of Defense Interface Standard for Shipboard Systems, D. C. Section 070 Magnetic Field Environment

MIL-STD-810G(1)

Test Methods, Environmental Engineering Considerations and Laboratory Tests

MIL-STD-108E Definitions of and Basic Requirements for Enclosures for Electric and Electronic Equipment
Air Particle Detector (APD) Noise Limit Specification
Interface Design Description for Air Particle Detector (APD) PPMC-78-IDD-RP-03 Rev F (Copies of specifications, standards, and handbooks required by manufacturers in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting officer.)
2.2. Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedence. 3.

RADIACMETER DESCRIPTION AND PERFORMANCE

3.1. Radiacmeter general description. The radiacmeter is a detection and monitoring system for radioactive particles suspended in the air. The radiacmeter is to be used whenever a continuous and accurate