Home / Replace Fisher House 1 HVAC System / Document

Bid document

Updated

A PDF document (3.6 MB) attached to Replace Fisher House 1 HVAC System, from the Department of Veterans Affairs. Due Oct 30, 2026, 1:00 PM (UTC-5).

File name: P01 - 33CS-68SI.pdf

Download the full documentSee the bid

The full file is for paid members, or buy this bid alone.

Preview

PREMIERLINK™

Retrofit Rooftop Controller
Version 3.x

Installation, Start-Up and
Configuration Instructions
Part Number 33CSPREMLK

Page

• SPACE TEMPERATURE (SPT) SENSOR

• SUPPLY AIR TEMPERATURE (SAT) SENSOR

• INDOOR AIR QUALITY CO2 SENSOR

• OUTDOOR AIR QUALITY CO2 SENSOR

• RELATIVE HUMIDITY SENSOR

• OUTDOOR AIR TEMPERATURE SENSOR

• OUTDOOR AIR ENTHALPY SWITCH/RECEIVER

• FILTER SWITCH

• LOCATION

• MOUNTING

• SPACE TEMPERATURE (SPT) SENSOR

INSTALLATION

• SUPPLY AIR TEMPERATURE (SAT) SENSOR

INSTALLATION

• INDOOR AIR QUALITY CO2 SENSOR

INSTALLATION

• OUTDOOR AIR QUALITY CO2 SENSOR

INSTALLATION

• HUMIDITY SENSOR (WALL-MOUNTED) INSTALLATION

• OUTDOOR AIR TEMPERATURE SENSOR

• FACTORY-INSTALLED CONTROLLER

• COMMUNICATIONS BUS WIRE SPECIFICATIONS

• OUTDOOR ENTHALPY CONTROL

• DIFFERENTIAL ENTHALPY CONTROL

• OUTDOOR AIR ENTHALPY SENSOR/

ENTHALPY CONTROLLER

• RETURN AIR ENTHALPY SENSOR

• Q769B ADAPTER

• Q769C ADAPTER

• DRIVE DIRECTION

• SWITCH SELECTION

• WIRING

Page

• THERMOSTAT MODE

• CCN SENSOR MODE

SAFETY CONSIDERATIONS

SAFETY NOTE

Air-conditioning equipment will provide safe and reliable service when operated within design specifications. The equipment should be operated and serviced only by authorized personnel who have a thorough knowledge of system operation, safety devices and emergency procedures.
Good judgement should be used in applying any manufacturer’s instructions to avoid injury to personnel or damage to equipment and property.

WARNING

Disconnect all power to the unit before performing maintenance or service. Unit may automatically start if power is not disconnected. Electrical shock and personal injury
could result.

CAUTION

An individual field-supplied 24-vac power transformer is recommended for each PremierLink controller. If the unit transformer is used but does not have enough power, damage to equipment may result. The field-supplied transformer must be less than 100 VA to meet UL (Underwriters Laboratories) Class 2.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53330016-01
Printed in U.S.A.
Form 33CS-68SI
Pg 1
5-11
Replaces: 33CS-67SI

SPACE TEMPERATURE (SPT) SENSOR — A fieldsupplied Carrier space temperature sensor is required to maintain space temperature in sensor mode. There are four sensors available for this application: • 33ZCT55SPT, space temperature sensor with override
button
• 33ZCT56SPT, space temperature sensor with override
button and set point adjustment

The beginning of the document. Download the full file to read on.

Other documents in this bid