Product
Specification

PREMIERLINK™

Retrofit Rooftop
Controller

33CSPREMLK

The PremierLink retrofit controllers
offer:
• continuous monitoring and
regulation of the rooftop unit
• compatibility with Carrier diagnostic
display tools
• other devices can read and write
data to the controller
• ability to connect unit to the Carrier
Comfort Network® (CCN) system

Features/Benefits
The PremierLink retrofit
rooftop controller is an
intelligent control that
continuously monitors and
regulates rooftop operation
with reliability and precision
that minimizes downtime to
ensure maximum occupant
comfort.

a33-9147

Copyright 2007 Carrier Corporation

The PremierLink controller is compatible with the Carrier Comfort Network (CCN) system. Carrier’s diagnostic standard tier display tools such as System Pilot™ or Touch Pilot™ device
can be used with the PremierLink controller. User interfaces include the CCN Service Tool, ComfortVIEW™ and
ComfortWORKS® software.
When the PremierLink controller is used
as part of the CCN system, other
devices such as the CCN data transfer,
3V™ linkage coordinator, or Comfort
Controller can read data from or write
data to the retrofit controller.

Form 33CS-33PS

Features/Benefits (cont)
Extensive control capabilities
The 33CSPREMLK retrofit controller
provides the following features and
benefits:
• provides software clock and local
occupancy schedule for local occupancy control (requires time broadcaster and hardware clock from another device in the system)
• uses remote timeclock input to provide occupancy control through external contacts or this input can be reconfigured for use with a door or
window switch to disable heating and
cooling if a door or window is left
open
• provides continous or intermittent fan
operation in the occupied mode
• features supply air temperature limiting and integrated safeties for DX (direct expansion), gas, electric and
heat pump units
• provides field tests that enables the
user to check output points and verify
their functionality
• controls two stages of DX cooling to
maintain space temperature set point
• ability to provide occupied and unoccupied dehumidification • controls up to 3 stages of gas heat or
combination of mechanical and electric heat to maintain space temperature set point • ability to control exhaust fan based on
economizer or occupancy on
2-stage heat units

The beginning of the document. Download the full file to read on.