ROSS SPRINGS-RED CANYON WATERLINE REPLACEMENT
1240LT27Q0022
Description –
A.
This project includes the replacement of 4” asbestos cement pipe (abandoned in place) with 4” HDPE water main and associated valves and connections to laterals.
B.
The work includes;
1.
Installation of 4450 linear feet of 4” HDPE pipeline, most of which will be shallow bury or laid on cleared ground and covered with imported fill from a government source.
2.
Cover an additional 1150 linear feet of existing pipeline with imported fill from a government source.
3.
Installation of 2 combination air-vacuum valves with utility boxes.
4.
Installing associated valves, daylight drains, and pumpout drains; and connecting to existing lateral mains and services.
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotations are being requested and a separate written solicitation will not be issued.
Solicitation number 1240LT27Q0022 is issued as a Request for Quotation (RFQ) for Ross Springs Waterline Replacement.
This acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 237110 The small business size standard is $45 This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency.
SCHEDULE OF ITEMS
ROSS SPRINGS-RED CANYON WATERLINE REPLACEMENT
Final (06/26/2026)
ITEM
NUMBER
DESCRIPTION
METHOD
OF MEAS
UNIT
QUANTITY
PRICE
TOTAL
BASE BID
011900-1
Mobilization
LSQ
LS
Lump Sum
024102-1
Removal and Disposal of Existing Structures
LSQ
LS
Lump Sum
133403-1
Utility Box - Concrete, 48" Dia. w/ Air-Vacuum Relief Valve
AQ
EA
DQ
LF
DQ
LF
DQ
LF
4475
221100-1
221100-2
221100-3
Pipeline - 1.5" HDPE, 250 PSI with Heat Fusion Joints,
Including Trench
Pipeline - 2" HDPE, 250 PSI with Heat Fusion Joints,
Including Trench
Pipeline - 4" HDPE, 250 PSI with Heat Fusion Joints,
Including Trench
221100-4
Pipe Sleeve - 5" GSP
DQ
LF
221100-5
Daylight Drain - 1" Screened
AQ
EA
221100-6
Daylight Drain - 1.5" Screened
AQ
EA
221100-7
Daylight Drain - 1.5" Screened, w/ Ball Valve (at Fire Hydrant)
AQ
EA
221100-8
Pumpout Drain - 1"
AQ
EA
221100-9
Pumpout Drain - 1.5"
AQ
EA
221102-1
Curb Box Only (Over Existing 1" Metal Valve)
AQ
EA
221102-2
Curb Box Only (Over Existing 2" Metal Valve)
AQ
EA
221102-3
Curb Box Only (Over Existing 4" Metal Valve)
AQ
EA
The beginning of the document. Download the full file to read on.