GENERAL PLAN SHEET NOTES

40' - 0"

N

W1

W1

6' - 0"

6' - 0"

14' - 0"

W1

6' - 0"

6' - 0"

128-3

9' - 4"

W1

W1

BDRM 3

6' - 0"

W1

6' - 0"

BDRM 2

BDRM 2

BDRM 3

BDRM 2

BDRM 1

128-2

127-2

127-3

126-2

126-1

BDRM 1

M8

128-1

.5h

127-1

JAN

W1

D6

8"

.5h

128-4

W2

H6

BDRM 5

A-311

128-5

2' - 4"

16' - 4"

K

A1
A-202

8' - 0"

J

6' - 0"

6' - 0"

3' - 4"

BDRM 4

16' - 0"

M8

127-4

10' - 0"

A6
A-202

7' - 4"

3' - 4"

7' - 4"

W2

7' - 4"

A16
A-701

BDRM 3

126-3

.5h

6' - 0"

6' - 0"

6' - 0"

W1

7' - 4"

3' - 4"

A2
A-520

1' - 4"

10' - 0"

W2

W1

W3

8"

UNIT

4' - 0"

UNIT

W3

8"

4' - 0"

3' - 8"

6' - 0"

4' - 0" 3' - 4" 2' - 8"

BDRM 4

10' - 8"

2' - 4"

6' - 0"

8"
7' - 8" 3' - 4" 2' - 8"

W3

8"

TYP

H.

DIMENSIONS OF EXTERIOR WALLS ARE TO EXTERIOR FACE OF CMU OR

CONCRETE UNLESS NOTED OTHERWISE.

I.

AT “ALIGN” NOTE, FINISH FACE OF WALLS TO ALIGN

J.

INSTALL ACOUSTIC BATT INSULATION IN ALL RESTROOM WALLS AND

WALLS CONTAINING PLUMBING PIPES.

K.

SEE SHEET G-004 FOR STANDARD AND ACCESSIBLE MOUNTING HEIGHTS

OF FIXTURES AND ACCESSORIES.

L.

REFER TO PLUMBING PLANS FOR FLOOR DRAINS AND CLEANOUTS.

M.

SEE ROOM FINISH SCHEDULE FOR ROOMS WHERE WINDOW TREATMENTS

ARE TO BE INSTALLED

N.

PROVIDE METAL AND/OR FIRE-RESISTANT WOOD BLOCKING AT ALL WALL

MOUNTED FIXTURES, FURNITURE, EQUIPMENT, ACCESSORIES, AND OTHER

SPECIALTIES.

O.

ALL EXPOSED PIPES, VENTS, AND CONDUIT PENETRATING WALLS, FLOORS, OR CEILINGS SHALL HAVE FINISHED TRIM RINGS (ESCUTCHEONS).

P.

FIRESTOP AROUND MECHANICAL AND ELECTRICAL EQUIPMENT, ETC. WITH

UL APPROVED FIRESTOPPING MATERIAL PER CODE AT ALL PENETRATIONS

IN FIRE RATED WALLS OR FLOORS.

Q.

EXTERIOR LANDINGS, STOOPS, BALCONIES, AND PORCHES SHALL BE

LEVEL ACROSS DOORWAYS AND SHALL SLOPE AWAY FROM THE BUILDING

AT 1/4" PER FOOT.

25' - 7"

6' - 0"

6' - 0"

14' - 0"

W1

3' - 4" 3' - 4"

MECH/

RISER

121-3

W1

A6

BDRM 1

D6

121-3

125-1

6' - 0"

M

KEYED NOTES

6' - 0"

6' - 0"

6' - 0"

W1

40' - 0"

W1

6' - 0"

6' - 0"

8' - 0"

A15
A-501

W1 7

W1

BDRM 2

BDRM 3

BDRM 2

125-2

124-3

124-2

.5h A

BDRM 2

BDRM

123-2

123-3

M8

124-1

.5h

D15
A-703

11' - 2"

9' - 9"

UNIT

BDRM 3

125-3

10' - 0"

3' - 4"

The beginning of the document. Download the full file to read on.